5 PD SERIES PUMPS PT / PG / PD REPAIR<br />

5.7 Cleaning Sediment Cup<br />

Turn fuel valve off. Remove sediment cup (a) and O-ring<br />

(b). Wash them thoroughly in a nonflammable solvent.<br />

Dry them and re-install. Turn fuel valve on and check for<br />

leaks.<br />

5.8 Adjusting Idle Speed<br />

To adjust idle speed:<br />

1. Start engine and allow it to warm up to normal operating<br />

temperature.<br />

2. Turn throttle stop screw (c) in to decrease speed, out<br />

to increase speed.<br />

5.9 Gear Case<br />

Check the oil level in the gear case once a week or every<br />

25 hours of operation.<br />

Remove oil level plug (e). Check that oil level is even with<br />

plug opening. If oil level is low, add oil through the top fill<br />

plug opening (d). Do not overfill.<br />

Change oil in gear case once a year or every 300 hours<br />

of operation.<br />

Drain oil through drain plug opening (f) at bottom of gear<br />

case. Add oil through fill plug on top of gear case.<br />

Oil capacity: 32 oz. (1000 ml) SAE 30<br />

5-6<br />

c<br />

e<br />

d<br />

b<br />

a<br />

1001SD13<br />

1017SD58<br />

f 1010SD50