3 PT SERIES PUMPS PT / PG / PD REPAIR<br />
3.4 Air Cleaner<br />
PT2A / PT3A / PT2B / PT2R<br />
Service air cleaner frequently to prevent carburetor malfunction.<br />
NEVER run engine without air cleaner. Severe engine<br />
damage will occur.<br />
The engine is equipped with a dual element air cleaner.<br />
1. Remove air cleaner cover (a). Remove both elements<br />
and inspect them for holes or tears. Replace elements<br />
if damaged. Undamaged elements may be<br />
cleaned and reused.<br />
2. To clean foam element (b):<br />
Wash in solution of mild detergent and warm water.<br />
Rinse thoroughly in clean water. Allow element to dry<br />
thoroughly. Once dry, soak element in clean engine<br />
oil and squeeze out excess.<br />
3. Paper element (c)<br />
Tap element lightly to remove excess dirt or blow<br />
compressed air through filter from the inside out.<br />
Replace paper element if it appears heavily soiled.<br />
3-6<br />
WARNING<br />
NEVER use gasoline or other types of low flash<br />
point solvents for cleaning the air cleaner. A fire or<br />
explosion could result.<br />
PT2R<br />
c<br />
a<br />
b<br />
1013SD75<br />
PT2A / PT3A<br />
PT2B<br />
b<br />
a<br />
c<br />
a<br />
c<br />
b<br />
1001SD12<br />
1006SD80