3 PT SERIES PUMPS PT / PG / PD REPAIR<br />

3.4 Air Cleaner<br />

PT2A / PT3A / PT2B / PT2R<br />

Service air cleaner frequently to prevent carburetor malfunction.<br />

NEVER run engine without air cleaner. Severe engine<br />

damage will occur.<br />

The engine is equipped with a dual element air cleaner.<br />

1. Remove air cleaner cover (a). Remove both elements<br />

and inspect them for holes or tears. Replace elements<br />

if damaged. Undamaged elements may be<br />

cleaned and reused.<br />

2. To clean foam element (b):<br />

Wash in solution of mild detergent and warm water.<br />

Rinse thoroughly in clean water. Allow element to dry<br />

thoroughly. Once dry, soak element in clean engine<br />

oil and squeeze out excess.<br />

3. Paper element (c)<br />

Tap element lightly to remove excess dirt or blow<br />

compressed air through filter from the inside out.<br />

Replace paper element if it appears heavily soiled.<br />

3-6<br />

WARNING<br />

NEVER use gasoline or other types of low flash<br />

point solvents for cleaning the air cleaner. A fire or<br />

explosion could result.<br />

PT2R<br />

c<br />

a<br />

b<br />

1013SD75<br />

PT2A / PT3A<br />

PT2B<br />

b<br />

a<br />

c<br />

a<br />

c<br />

b<br />

1001SD12<br />

1006SD80