METALS<br />

Adjust pH <strong>of</strong> their aqueous solution to 3.0 to 3.5 (using bromophenol<br />

blue indicator) with NH 4 OH. Precipitate lead <strong>and</strong> some other metals<br />

from the solution as sulphides, with H 2 S using 5 to 10 mg <strong>of</strong> CuSO 4 as<br />

co-precipitant. Filter, boil filtrate to expel excess H 2 S completely <strong>and</strong><br />

refilter, if necessary to obtain clear solution.<br />

(Ref:- Manual Methods <strong>of</strong> Analysis for Adulterants <strong>and</strong> Contaminants<br />

in Foods I.C.M. R, 1990 Page137)<br />

2.0 DETERMINATION OF LEAD, CADMIUM, COPPER, IRON AND<br />

ZINC IN FOODS BY ATOMIC ABSORPTION<br />

SPECTROPHOTOMETER<br />

Principle:<br />

Test portions are dried <strong>and</strong> then ashed at 450 0 C under a gradual increase<br />

(about 50 0 C / hr) in temperature, 6 N HCl (1+1) is added <strong>and</strong> the solution is<br />

evaporated to dryness. The residue is dissolved in 0.1N HNO 3 <strong>and</strong> the<br />

analytes are determined by flame <strong>and</strong> graphite procedures.<br />

Apparatus<br />

(a) Atomic absorption Spectrophotometer – with an air – acetylene<br />

burner or nitrous oxide- acetylene burner for flame <strong>and</strong> a graphite<br />

furnace for electrothermal determinations with appropriate<br />

background (non atomic correction). Instrument parameters are<br />