METALS<br />
Adjust pH <strong>of</strong> their aqueous solution to 3.0 to 3.5 (using bromophenol<br />
blue indicator) with NH 4 OH. Precipitate lead <strong>and</strong> some other metals<br />
from the solution as sulphides, with H 2 S using 5 to 10 mg <strong>of</strong> CuSO 4 as<br />
co-precipitant. Filter, boil filtrate to expel excess H 2 S completely <strong>and</strong><br />
refilter, if necessary to obtain clear solution.<br />
(Ref:- Manual Methods <strong>of</strong> Analysis for Adulterants <strong>and</strong> Contaminants<br />
in Foods I.C.M. R, 1990 Page137)<br />
2.0 DETERMINATION OF LEAD, CADMIUM, COPPER, IRON AND<br />
ZINC IN FOODS BY ATOMIC ABSORPTION<br />
SPECTROPHOTOMETER<br />
Principle:<br />
Test portions are dried <strong>and</strong> then ashed at 450 0 C under a gradual increase<br />
(about 50 0 C / hr) in temperature, 6 N HCl (1+1) is added <strong>and</strong> the solution is<br />
evaporated to dryness. The residue is dissolved in 0.1N HNO 3 <strong>and</strong> the<br />
analytes are determined by flame <strong>and</strong> graphite procedures.<br />
Apparatus<br />
(a) Atomic absorption Spectrophotometer – with an air – acetylene<br />
burner or nitrous oxide- acetylene burner for flame <strong>and</strong> a graphite<br />
furnace for electrothermal determinations with appropriate<br />
background (non atomic correction). Instrument parameters are<br />
8