21.06.2012 Views

20111104_CN.12_complete_UK_LOW.pdf

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MIXO<br />

160<br />

MIXO modular units 1 pole 200A - 1000V<br />

the modular inserts must be installed in suitable<br />

frames which are then mounted in traditional<br />

housings * or COB panel support<br />

frames for modular units * ............ page: 195<br />

* enclosures: housings or high construction hoods<br />

modular units, 200A silver plated crimp contacts<br />

crimp connections heat shrink tube<br />

description part No. part No.<br />

without contacts (to be ordered separately)<br />

- female inserts for female contacts CX 01 YF<br />

- male inserts for female contacts<br />

200A female crimp contacts<br />

CX 01 YM<br />

16 mm2 AWG 6 one groove (back side) CYFA 16<br />

25 mm2 AWG 4 with no grooves CYFA 25<br />

35 mm2 AWG 2 one groove CYFA 35<br />

50 mm2 AWG 1 two grooves CYFA 50<br />

70 mm2 AWG 2/0 with no grooves CYFA 70<br />

200A male crimp contacts<br />

16 mm2 AWG 6 one groove (back side) CYMA 16<br />

25 mm2 AWG 4 with no grooves CYMA 25<br />

35 mm2 AWG 2 one groove CYMA 35<br />

50 mm2 AWG 1 two grooves CYMA 50<br />

70 mm2 AWG 2/0 with no grooves CYMA 70<br />

heat shrink tube for CYFA/CYMA 16 contacts or for CR TT<br />

conductor with total external Ø < 10 mm<br />

- characteristics according to EN 61984:<br />

200A 1000V 8kV 3<br />

200A 920/1600V 8kV 2<br />

- certifications: (cUL - UL for USA and Canada),<br />

(CSA), (CCC), (GL); the certifications shown in<br />

brackets are being applied for<br />

- rated voltage according to UL/CSA: 600V<br />

- insulation resistance: ≥ 10 GΩ<br />

- ambient temperature limit: -40 °C ... +125 °C<br />

- are made of self-extinguishing thermoplastic resin UL 94 V0<br />

- mechanical life: ≥ 500 cycles<br />

- contact resistance: ≤ 0,2 mΩ<br />

- for maximum current load, see the following load<br />

curves inserts, for more information see page 499<br />

courant d’exercice (A)<br />

200<br />

190<br />

180<br />

170<br />

160<br />

150<br />

140<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

diagramme CX 01 Y - 1 pôle (MIXO 200A)<br />

25 mm 2<br />

50 mm 2 70 mm 2<br />

35 mm 2<br />

0<br />

0 10 20 30 40 50 60 70 80 90 100 110 120 130<br />

température ambiante (°C)<br />

dimensions shown are not binding<br />

and may be changed without notice<br />

dimensions in mm dimensions in mm<br />

34 29.4<br />

contacts side (front view)<br />

side with reference arrow ▲<br />

- 2 frame slots<br />

F<br />

NEW<br />

M<br />

52.3<br />

57.8<br />

M<br />

F<br />

CYF and CYM<br />

ø A<br />

40<br />

ø 20<br />

ø 9.5<br />

ø 20<br />

38<br />

ø A<br />

silver plated<br />

CYF and CYM contacts<br />

conductor conductor conductor<br />

section slot stripping<br />

ø A lenght<br />

(mm2 ) (mm) (mm)<br />

16 6.1 15<br />

25 7.0 15<br />

35 8.2 15<br />

50 9.8 15<br />

70 11.8 15<br />

heat shrink tube<br />

YES NO<br />

90/100 °C<br />

CR TT