21.06.2012 Views

20111104_CN.12_complete_UK_LOW.pdf

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MIXO modular units 2 poles 100A - 1000V<br />

the modular inserts must be installed in suitable<br />

frames which in turn are installed in traditional<br />

housings * or COB panel support<br />

frames for modular units * ............ page: 195<br />

* enclosures: bulkhead mounting housings, high<br />

construction housings or high construction hoods<br />

modular units, 100A silver plated crimp contacts,<br />

crimp connections PE adapter<br />

description part No. part No.<br />

without contacts (to be ordered separately)<br />

- female inserts for female contacts ** CX 02 GF<br />

- male inserts for female contacts ** CX 02 GM<br />

100A female crimp contacts<br />

16 mm 2 AWG 6 - 5 CGFA 16<br />

25 mm 2 AWG 4 - 3 CGFA 25<br />

35 mm 2 AWG 2 CGFA 35<br />

100A male crimp contacts<br />

16 mm 2 AWG 6 - 5 CGMA 16<br />

25 mm 2 AWG 4 - 3 CGMA 25<br />

35 mm 2 AWG 2 CGMA 35<br />

cable earthing adapter 16 mm 2 (AWG 6 - 5) CGT 16<br />

** on request, version with pole 3/4 numbering,<br />

references: CX 02 GFN, CX 02 GMN<br />

- characteristics according to EN 61984:<br />

100A 1000V 8kV 3<br />

100A 920/1600V 8kV 2<br />

- certifications: cUL (UL for USA and Canada), CCC,<br />

GL, GOST<br />

- rated voltage according to UL/CSA: 600V<br />

- insulation resistance: ≥ 10 GΩ<br />

- ambient temperature limit: -40 °C ... +125 °C<br />

- are made of self-extinguishing thermoplastic resin UL<br />

94 V0<br />

- mechanical life: ≥ 500 cycles<br />

- contact resistance: ≤ 0.3 mΩ<br />

- for contact crimping instructions, please see the<br />

crimping tool section (100A contacts, CGF and CGM<br />

series) on page 476<br />

- for maximum current load, see the following load<br />

curves inserts, for more information see page 499<br />

working current (A)<br />

140<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

diagram CX 02 poles (MIXO 100A)<br />

0<br />

0 10 20 30 40 50 60 70 80 90 100 110 120 130<br />

ambient temperature (°C)<br />

dimensions shown are not binding<br />

and may be changed without notice<br />

dimensions in mm dimensions in mm<br />

34 29.4<br />

contacts side (front view)<br />

side with reference arrow ▲<br />

F<br />

- footprint 2 modules<br />

M<br />

49<br />

51<br />

M<br />

F<br />

silver plated<br />

CGF and CGM CGT 16<br />

ø A<br />

15.5<br />

15.5<br />

ø C<br />

ø 8<br />

37<br />

ø C<br />

ø B<br />

39.5<br />

8<br />

ø 5.5<br />

ø 4.6<br />

15<br />

26<br />

CGF and CGM contacts<br />

conductor conductor slot conductor<br />

section ø A ø B ø C stripping lenght<br />

(mm2 ) (mm) (mm) (mm) (mm)<br />

16 5.5 5.5 13 15<br />

25 7.0 7.0 13 15<br />

35 7.9 8.2 12.5 15<br />

How to use the PE adapter (CGT 16):<br />

1) Strip 15 mm of flexible PE protective cable<br />

2) Crimp the cable on the CGT 16 adapter by using the<br />

CGPZ pliers with the CGD 16 C matrix<br />

3) Fix the adapter tip in the larger earth terminal<br />

(6 mm 2 ) of frames CX...TM/TF<br />

4) To be used with bulkhead mounting housings or<br />

high construction hoods<br />

5) Cannot be used with T-TYPE series<br />

163<br />

MIXO

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!