load curves<br />

500<br />

limit current curves of the inserts<br />

series MIXO (CX 02 4A/B, CX 03, CX 03 4B, CX 3/4) series MIXO (CX 04, CX 05, CX 06, CX 08) series MIXO (CX 12, CX 17, CX 20)<br />

curves curves curves<br />

working current (A)<br />

working current (A)<br />

working current (A)<br />

working current (A)<br />

diagram CX 02 4A/B poles<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

diagram CX 03 poles<br />

50<br />

40<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

0<br />

0 10 20 30 40 50 60 70 80 90 100 110 120 130<br />

5<br />

2,5 mm 2<br />

ambient temperature (°C)<br />

4,0 mm 2<br />

0<br />

0 10 20 30 40 50 60 70 80 90 100 110 120 130<br />

ambient temperature (°C)<br />

diagram CX 03 4B poles<br />

50<br />

40<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

diagram CX 3/4 poles<br />

50<br />

40<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

2,5 mm 2<br />

4,0 mm 2<br />

4,0 mm 2<br />

6,0 mm 2<br />

6,0 mm 2<br />

10 mm 2<br />

0<br />

0 10 20 30 40 50 60 70 80 90 100 110 120 130<br />

ambient temperature (°C)<br />

6,0 mm 2<br />

0<br />

0 10 20 30 40 50 60 70 80 90 100 110 120 130<br />

ambient temperature (°C)<br />

working current (A)<br />

working current (A)<br />

working current (A)<br />

working current (A)<br />

diagram CX 04 poles<br />

50<br />

40<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

diagram CX 05 poles<br />

20<br />

16<br />

14<br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

0<br />

0 10 20 30 40 50 60 70 80 90 100 110 120 130<br />

ambient temperature (°C)<br />

diagram CX 06 poles<br />

20<br />

16<br />

14<br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

0<br />

0 10 20 30 40 50 60 70 80 90 100 110 120 130<br />

ambient temperature (°C)<br />

16<br />

14<br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

4,0 mm 2<br />

1,5 mm 2<br />

1,5 mm 2<br />

diagram CX 08 poles<br />

1,5 mm 2<br />

6,0 mm 2<br />

0<br />

0 10 20 30 40 50 60 70 80 90 100 110 120 130<br />

ambient temperature (°C)<br />

2,5 mm 2<br />

2,5 mm 2<br />

2,5 mm 2<br />

4,0 mm 2<br />

0<br />

0 10 20 30 40 50 60 70 80 90 100 110 120 130<br />

ambient temperature (°C)<br />

working current (A)<br />

working current (A)<br />

working current (A)<br />

15<br />

14<br />

12<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

1,0 mm 2<br />

1,5 mm 2<br />

0<br />

0 10 20 30 40 50 60 70 80 90 100 110 120 130<br />

15<br />

14<br />

12<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

20<br />

16<br />

14<br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

diagram CX 12 poles<br />

ambient temperature (°C)<br />

diagram CX 17 poles<br />

1,0 mm 2<br />

0<br />

0 10 20 30 40 50 60 70 80 90 100 110 120 130<br />

diagram CX 20 poles<br />

1,5 mm 2<br />

2,5 mm 2<br />

1,5 mm 2<br />

ambient temperature (°C)<br />

4,0 mm 2<br />

0<br />

0 10 20 30 40 50 60 70 80 90 100 110 120 130<br />

ambient temperature (°C)