21.06.2012 Views

20111104_CN.12_complete_UK_LOW.pdf

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

limit current curves of the inserts<br />

CK...RY series CD series CT and CTS (10A) series<br />

CD series<br />

curves curves curves<br />

working current (A)<br />

working current (A)<br />

working current (A)<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

80<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

80<br />

16<br />

15<br />

14<br />

12<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

diagram CK...RY 03 poles<br />

1,0 mm 2<br />

1,5 mm 2<br />

1,5 mm 2<br />

0,5 mm 2<br />

diagram CD 07 and 08 poles<br />

1,0 mm 2<br />

2,5 mm 2<br />

90 100 110 120 130 140 150 160 170 180 190<br />

ambient temperature (°C)<br />

diagram CK...RY 04 poles<br />

1,0 mm 2<br />

1,5 mm 2<br />

0,5 mm 2<br />

2,5 mm 2<br />

90 100 110 120 130 140 150 160 170 180 190<br />

ambient temperature (°C)<br />

0<br />

0 10 20 30 40 50 60 70 80 90 100 110 120 130<br />

ambient temperature (°C)<br />

2,5 mm 2<br />

working current (A)<br />

working current (A)<br />

working current (A)<br />

working current (A)<br />

16<br />

15<br />

14<br />

12<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

0<br />

0 10 20 30 40 50 60 70 80 90 100 110 120 130<br />

16<br />

15<br />

14<br />

12<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

1,0 mm 2<br />

1,5 mm 2<br />

2,5 mm 2<br />

0<br />

0 10 20 30 40 50 60 70 80 90 100 110 120 130<br />

16<br />

15<br />

14<br />

12<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

1,5 mm 2<br />

1,0 mm 2<br />

2,5 mm 2<br />

0<br />

0 10 20 30 40 50 60 70 80 90 100 110 120 130<br />

ambient temperature (°C)<br />

16<br />

15<br />

14<br />

12<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

diagram CD 15 poles<br />

diagram CD 25 and 50 poles<br />

ambient temperature (°C)<br />

diagram CD 40 and 80 poles<br />

diagram CD 64 and 128 poles<br />

1,5 mm 2<br />

1,0 mm 2<br />

1,5 mm 2<br />

1,0 mm 2<br />

2,5 mm 2<br />

ambient temperature (°C)<br />

2,5 mm 2<br />

0<br />

0 10 20 30 40 50 60 70 80 90 100 110 120 130<br />

ambient temperature (°C)<br />

working current (A)<br />

working current (A)<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

0<br />

0 10 20 30 40 50 60 70 80 90 100 110 120 130<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

diagram CT and CTS 40 poles<br />

1,5 mm 2<br />

diagram CT and CTS 64 poles<br />

1,5 mm 2<br />

0,75 mm 2<br />

0,75 mm 2<br />

2,5 mm 2<br />

ambient temperature (°C)<br />

2,5 mm 2<br />

0<br />

0 10 20 30 40 50 60 70 80 90 100 110 120 130<br />

ambient temperature (°C)<br />

493<br />

load curves

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!