Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR MASK,<br />

CHEMICAL-BIOLOGICAL: M45 (con’t)<br />

ITEM<br />

NO.<br />

6<br />

con' t<br />

INTERVAL LOCATION PROCEDURE NOT FULLY MISSION<br />

CAPABLE IF:<br />

ITEM TO<br />

CHECK/<br />

SERVICE<br />

After<br />

Outlet<br />

Valve Disk<br />

and Outlet<br />

Valve<br />

Cover<br />

d. Check outlet valve<br />

seat (4) for dirt, nicks, or<br />

cracks. Smooth outlet<br />

valve disk (3) so it lies<br />

flat on seat.<br />

Outlet valve seat is<br />

nicked or cracked, or<br />

disk will not seat<br />

properly.<br />

e. Check that barb (5) is<br />

not broken or cracked.<br />

f. Wipe moisture and dirt<br />

from outlet valve cover<br />

(2) with cheesecloth (item<br />

3, app D) and check for<br />

cuts, tears or holes.<br />

Barb is cracked or<br />

broken.<br />

Outlet valve cover is<br />

cut, torn, has holes, or<br />

will not seat firmly over<br />

outlet valve.<br />

g. Reinstall cover.<br />

2-25