Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR MASK,<br />

CHEMICAL-BIOLOGICAL: M45 (con’t)<br />

ITEM<br />

NO.<br />

12<br />

con' t<br />

INTERVAL LOCATION PROCEDURE NOT FULLY MISSION<br />

CAPABLE IF:<br />

ITEM TO<br />

CHECK/<br />

SERVICE<br />

After Nosecup b. Check that nosecup<br />

and nosecup valve seats<br />

are free of dirt. Check<br />

nosecup for cracks, cuts,<br />

tears or holes. Look at<br />

the inside of nosecup<br />

inner lip where it touches<br />

your skin.<br />

Nosecup is dirty,<br />

cracked, cut, or has<br />

holes.<br />

Nosecup valve seats<br />

are dirty.<br />

c. Rotate nosecup valve<br />

disks (4) to ensure they<br />

are not stuck. Check that<br />

valve disks are not dirty,<br />

curled, or torn.<br />

Nosecup valve disks<br />

are torn, missing, dirty,<br />

or stuck to nosecup<br />

2-33