Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR MASK,<br />

CHEMICAL-BIOLOGICAL: M45 (con’t)<br />

ITEM<br />

NO.<br />

INTERVAL LOCATION PROCEDURE NOT FULLY MISSION<br />

CAPABLE IF:<br />

ITEM TO<br />

CHECK/<br />

SERVICE<br />

11 After Inlet Valve<br />

Assembly<br />

a. Fold back left side of<br />

nosecup to fully expose<br />

inlet valve assembly.<br />

Check that inlet valve<br />

disk (1) is present and<br />

properly positioned on<br />

the cage and post<br />

assembly (2).<br />

Inlet valve disk is<br />

missing or not<br />

positioned on the cage<br />

and post assembly.<br />

b. Check inlet valve<br />

disk (1) for tears, curls or<br />

cleanliness. Make sure<br />

inlet valve disk lies flat.<br />

Inlet valve disk has<br />

tears, curls, or does not<br />

seat against inlet valve<br />

gasket.<br />

2-30