The Main Setup Menu<br />

The Over Level menu allows you to set the parameters listed in Table 4‐3.<br />

Table 4-3<br />

Over Level Alarm Parameters<br />

Menu Item Controls Range<br />

Alarm Enables or disables the alarm. Enabled/Disabled<br />

Threshold The loudness threshold for the alarm. The alarm triggers if 1 to 31 dB<br />

the measured loudness value exceeds the loudness<br />

reference plus the threshold for the duration specified in<br />

Time.<br />

Time The duration of the over‐level condition required to trigger 0 to 300 seconds<br />

the alarm.<br />

Under Level<br />

The under‐level alarm is triggered when the input signal loudness level falls below the<br />

chosen threshold relative to the selected digital or analog loudness reference level. This<br />

alarm is useful for identifying silence and/or near‐silent conditions.<br />

The Under Level menu allows you to set the parameters listed in Table 4‐4.<br />

Table 4-4<br />

Under-Level Alarm Parameters<br />

Menu Item Controls Range<br />

Alarm Enables or disables the alarm. Enabled/Disabled<br />

Threshold The loudness threshold for the alarm. The alarm 1 to 31 dB<br />

triggers if the measured loudness value falls below<br />

the loudness reference minus the threshold for the<br />

duration specified in Time.<br />

Time<br />

The duration of the under‐level condition required 0 to 300 seconds<br />

to trigger the alarm.<br />

Table 4-5<br />

Under-Level Alarm Parameters<br />

Menu Item Controls Range<br />

Alarm Enables or disables the alarm. Enabled/Disabled<br />

Threshold The loudness threshold for the alarm. The alarm 1 to 31 dB<br />

triggers if the measured loudness value falls below<br />

the loudness reference minus the threshold for the<br />

duration specified in Time.<br />

Time<br />

The duration of the under‐level condition required 0 to 300 seconds<br />

to trigger the alarm.<br />

dialnorm Threshold<br />

The dialnorm Threshold alarm is triggered when the measured loudness value of the<br />

input signal deviates from the dialnorm value already carried within the <strong>Dolby</strong> E or<br />

<strong>Dolby</strong> Digital input stream. This alarm is useful for identifying <strong>Dolby</strong> E and <strong>Dolby</strong> Digital<br />

bitstreams with incorrect dialogue level values.<br />

The dialnorm Threshold menu allows you to set the parameters listed in Table 4‐6.<br />

Table 4-6<br />

dialnorm Threshold Alarm Parameters<br />

Menu Item Controls Range<br />

Alarm Enables or disables the alarm. Enabled/Disabled<br />

<strong>Dolby</strong> ® <strong>LM100</strong> <strong>Broadcast</strong> <strong>Loudness</strong> <strong>Meter</strong> User’s <strong>Manual</strong> 33