6. ENVIRONMENTAL SAFETY and HEALTH<br />

6.1 Findings and Comments<br />

The NOνA ES&H review addressed planning for construction and R&D Integrated<br />

Safety Management (ISM). NOνA management and staff vocalized and demonstrated support of<br />

ISM functions and principles. The ES&H aspects of NOνA are adequately addressed for this<br />

stage of the project.<br />

Since the primary construction activity, the Far Detector Laboratory is planned for a<br />

Minnesota site, a primary NOνA project environmental assessment will be conducted to satisfy<br />

the Minnesota state rules. The project is required to have an approved Environmental<br />

Assessment Worksheet (EAW) for Minnesota, and NOνA holds documentation stating that the<br />

University of Minnesota will be responsible for submitting the EAW as the responsible<br />

government unit (RGU). The EAW will meet DOE requirements for the Minnesota site. NOνA<br />

management anticipated the need for additional environmental assessments for NOνA LS<br />

blending activities performed onsite by Fermilab.<br />

NEPA documentation for the construction phase of the project was developed.<br />

The NOνA team drafted a Preliminary Hazard Analysis, (NuMI) <strong>Off</strong>-<strong>Axis</strong> ν e <strong>Appearance</strong><br />

Experiment Hazard Analysis <strong>Document</strong> on November 11, 2005. The document is substantial<br />

and the team anticipates updating the plan as the project tasks are finalized. For example, if<br />

NOνA LS blending activities are performed onsite by Fermilab, then a more complete discussion<br />

of blending hazards is warranted. When an epoxy system is selected, the occupational health<br />

impact of sensitization to the epoxy components should be included. The confined spaces safety<br />

considerations required for the project should also be discussed.<br />

The schedule for completion of ES&H documents before CD-2 is reasonable.<br />

6.2 Recommendations<br />

1. Include ES&H criteria in selection of mineral oil if a “mildly refined” mineral oil is<br />