Download - Odeon
Download - Odeon
Download - Odeon
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
2.3 Pre-calculated Rooms – Round Robins<br />
<strong>Odeon</strong>©1985-2005<br />
4<br />
6<br />
1<br />
calculated by ODEON with those measured in the real<br />
rooms:<br />
P1<br />
3<br />
P2<br />
5<br />
2<br />
At this point you have tried the basic functions in<br />
ODEON and may want to view results for more<br />
realistic rooms. In the room directory you will find<br />
pre-calculated results in the rooms Elmia RoundRobin2<br />
detailed.par and PTB_Studio open curtains detailed model.par which<br />
were the rooms used as test objects in the 2 nd and 3 rd<br />
Round Robins (Bork, 2000; Bork, 2005). Geometry,<br />
absorption data, source and receiver positions as well<br />
as the measured room acoustical parameters are<br />
those supplied to all participants in the Round Robins,<br />
by the PTB in Germany - these data are publicly<br />
available at www.ptb.de. To compare results<br />
<br />
<br />
<br />
<br />
Open the room in question.<br />
Open the JobList – the Shift+Ctrl+J shortcut.<br />
Select one of the pre-calculated Multi point response<br />
jobs (job one or two) in the Joblist and open it –<br />
the Alt+M shortcut.<br />
Select the Measured versus simulated tab-sheet in the Multi<br />
Point display.<br />
1<br />
P2<br />
P1<br />
3<br />
2<br />
<strong>Odeon</strong>©1985-2005<br />
A couple of other examples<br />
Hagia Irene.par is a model of a Byzantine church in<br />
Istanbul which like the examples above also includes<br />
the measured room acoustical parameters.<br />
10<br />
9<br />
7<br />
3<br />
8<br />
2<br />
1<br />
P1<br />
11<br />
4 5<br />
6<br />
<strong>Odeon</strong>©1985-2005<br />
22<br />
20<br />
S29 S27<br />
S25 S26<br />
19 S31 S32 S34 S35<br />
S24 S30 S33 S37 S38<br />
18<br />
S36 S40<br />
P41 P22<br />
P23 P42 13<br />
17 S39<br />
21<br />
S28 15<br />
14<br />
23 16<br />
<strong>Odeon</strong>©1985-2007<br />
24<br />
11<br />
12<br />
10 8<br />
S8S6 S4 7 S10 S11S13<br />
S14<br />
6<br />
S3 S9 S12 S16 S17<br />
P21 S15 S20<br />
P19P21 P44<br />
1<br />
5S18<br />
9 S7 3 2<br />
4<br />
Another example Studstrup.par is also available;<br />
this is a model of a turbine hall at a power<br />
plant – measured SPL(A) is included in that<br />
example. This example is only available for<br />
the Industrial and Combined editions.<br />
If you wish to carry out faster calculations, you may enter the Room setup and select the Engineering<br />
setting this will provide results approximately 2 times faster without much loss in quality in<br />
results.<br />
2-33