02.05.2014 Views

Download - Odeon

Download - Odeon

Download - Odeon

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

2.3 Pre-calculated Rooms – Round Robins<br />

<strong>Odeon</strong>©1985-2005<br />

4<br />

6<br />

1<br />

calculated by ODEON with those measured in the real<br />

rooms:<br />

P1<br />

3<br />

P2<br />

5<br />

2<br />

At this point you have tried the basic functions in<br />

ODEON and may want to view results for more<br />

realistic rooms. In the room directory you will find<br />

pre-calculated results in the rooms Elmia RoundRobin2<br />

detailed.par and PTB_Studio open curtains detailed model.par which<br />

were the rooms used as test objects in the 2 nd and 3 rd<br />

Round Robins (Bork, 2000; Bork, 2005). Geometry,<br />

absorption data, source and receiver positions as well<br />

as the measured room acoustical parameters are<br />

those supplied to all participants in the Round Robins,<br />

by the PTB in Germany - these data are publicly<br />

available at www.ptb.de. To compare results<br />

<br />

<br />

<br />

<br />

Open the room in question.<br />

Open the JobList – the Shift+Ctrl+J shortcut.<br />

Select one of the pre-calculated Multi point response<br />

jobs (job one or two) in the Joblist and open it –<br />

the Alt+M shortcut.<br />

Select the Measured versus simulated tab-sheet in the Multi<br />

Point display.<br />

1<br />

P2<br />

P1<br />

3<br />

2<br />

<strong>Odeon</strong>©1985-2005<br />

A couple of other examples<br />

Hagia Irene.par is a model of a Byzantine church in<br />

Istanbul which like the examples above also includes<br />

the measured room acoustical parameters.<br />

10<br />

9<br />

7<br />

3<br />

8<br />

2<br />

1<br />

P1<br />

11<br />

4 5<br />

6<br />

<strong>Odeon</strong>©1985-2005<br />

22<br />

20<br />

S29 S27<br />

S25 S26<br />

19 S31 S32 S34 S35<br />

S24 S30 S33 S37 S38<br />

18<br />

S36 S40<br />

P41 P22<br />

P23 P42 13<br />

17 S39<br />

21<br />

S28 15<br />

14<br />

23 16<br />

<strong>Odeon</strong>©1985-2007<br />

24<br />

11<br />

12<br />

10 8<br />

S8S6 S4 7 S10 S11S13<br />

S14<br />

6<br />

S3 S9 S12 S16 S17<br />

P21 S15 S20<br />

P19P21 P44<br />

1<br />

5S18<br />

9 S7 3 2<br />

4<br />

Another example Studstrup.par is also available;<br />

this is a model of a turbine hall at a power<br />

plant – measured SPL(A) is included in that<br />

example. This example is only available for<br />

the Industrial and Combined editions.<br />

If you wish to carry out faster calculations, you may enter the Room setup and select the Engineering<br />

setting this will provide results approximately 2 times faster without much loss in quality in<br />

results.<br />

2-33

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!