category is a calculation of the differences in diameter of the container across the<br />

parting line versus turned 90 degrees from the parting line. The decreased<br />

warpage is best attributed to the uniformity of the wall thickness at the measuring<br />

point. The container diameter was measured 3 inches from the bottom of the<br />

container at point 8 of the wall thickness measurements. Review of the wall<br />

thickness found in Appendix A proves that decrease of warpage is not related to<br />

varying wall thickness around the container. The likely reason for reduced<br />

warpage of the container is the internal cooling. Container thickness at the<br />

diameter measuring point is relatively thin and would receive the most cooling.<br />

This proves that the Fasti unit will actually “freeze” the container in place with<br />

more thorough cooling.<br />