protection as required within the FBC, Building or FBC,<br />
Residential for new construction must be provided.<br />
Exception: single family residential structures permitted<br />
subject to the FBC are not required to comply with this<br />
section.<br />
105.22 Demolition: Application for building permits for the<br />
work <strong>of</strong> demolition <strong>of</strong> buildings or structures, if such building or<br />
structure is over 12 feet in extreme height above grade or any<br />
wall <strong>of</strong> which is over 40 feet in horizontal length, shall be<br />
accepted from only qualified persons or firms. Qualifications <strong>of</strong><br />
persons or firms shall be in accordance with separate ordinance<br />
providing for qualification and certification <strong>of</strong> construction<br />
tradesmen.<br />
105.22.1 A permit for the demolition <strong>of</strong> a building or structure<br />
for which an application is made voluntarily by the<br />
owner shall expire sixty (60) days from the date <strong>of</strong> issuance,<br />
and shall specifically require the completion <strong>of</strong> the work for<br />
which the permit is issued on or before the expiration date.<br />
105.22.2 A permit for the demolition <strong>of</strong> a building or structure<br />
issued pursuant to a judicial order or an AHJ order having<br />
jurisdiction <strong>of</strong> the building or structure shall expire in<br />
accordance with the provisions <strong>of</strong> such order, and shall require<br />
completion <strong>of</strong> the work for which the permit is issued<br />
on or before the expiration date <strong>of</strong> the permit.<br />
105.23 Moving <strong>of</strong> Building and Structures.<br />
105.23.1 Before a building permit for moving a building or<br />
structure within or into the jurisdiction adopting this Code<br />
shall be approved or issued, such building or structures shall<br />
be inspected by the Building Official; upon request <strong>of</strong> the<br />
owner or his/her agent, and the Building Official shall ascertain<br />
that this Code and all other laws or ordinances applicable<br />
thereto shall be satisfied.<br />
105.23.2 Application for permit shall be submitted in<br />
such form as the Building Official may prescribe and<br />
shall be accompanied by such plans and/or specifications<br />
or other data as, in the opinion <strong>of</strong> the Building Official,<br />
is necessary to show compliance with the Code or<br />
the zoning regulations.<br />
SECTION 106<br />
FLOOR AND ROOF DESIGN LOADS<br />
106.1 Live loads posted. Where the live loads for which each<br />
floor or portion there<strong>of</strong> <strong>of</strong> a commercial or industrial building is<br />
or has been designed to exceed 50 psf (2.40 kN/m2), such design<br />
live loads shall be conspicuously posted by the owner in that part<br />
<strong>of</strong> each story in which they apply, using durable signs. It shall be<br />
unlawful to remove or deface such notices.<br />
106.2 Issuance <strong>of</strong> certificates <strong>of</strong> occupancy. A certificate <strong>of</strong><br />
occupancy required by Section 111 shall not be issued until the<br />
floor load signs, required by Section 106.1, have been installed.<br />
Broward County Board <strong>of</strong> Rules and Appeals<br />
Effective Date: March 15, 2012<br />
106.3 Restrictions on loading. It shall be unlawful to place, or<br />
cause or permit to be placed, on any floor or ro<strong>of</strong> <strong>of</strong> a building,<br />
structure or portion there<strong>of</strong>, a load greater than is permitted by<br />
this code.<br />
SECTION 107<br />
SUBMITTAL DOCUMENTS<br />
107.1 General.<br />
107.1.1 Submittal documents. Construction documents,<br />
special inspections and structural observation programs, and<br />
other data shall be submitted in two or more sets <strong>of</strong> plans<br />
and/or specifications as described in section 107.3 with each<br />
application for a permit. The application for permit shall be<br />
inscribed with the application date and the date <strong>of</strong> the Code<br />
in effect as set forth herein. The construction documents<br />
shall be prepared by a registered design pr<strong>of</strong>essional where<br />
required by Chapter 471, Florida Statutes or Chapter 481,<br />
Florida Statutes and this Code. Where special conditions<br />
exist, the Building Official is authorized to require additional<br />
construction documents to be prepared by a registered design<br />
pr<strong>of</strong>essional.<br />
Exception: The building <strong>of</strong>ficial is authorized to waive the<br />
submission <strong>of</strong> construction documents and other data not<br />
required to be prepared by a registered design pr<strong>of</strong>essional if<br />
it is found that the nature <strong>of</strong> the work applied for is such that<br />
review <strong>of</strong> construction documents is not necessary to obtain<br />
compliance with this code.<br />
107.1.2 Where required by the Building Official and/or Fire<br />
Marshal/Fire Code Official, a third copy <strong>of</strong> the plan showing<br />
parking, landscaping and drainage shall be provided.<br />
107.2 Construction documents. Construction documents shall<br />
be in accordance with Section 107.2.1 through 107.2.7.<br />
107.2.1 Information on construction documents. Construction<br />
documents shall be dimensioned and drawn upon<br />
suitable material. Electronic media documents are permitted<br />
to be submitted when approved by the Building Official.<br />
Construction documents shall be <strong>of</strong> sufficient clarity to indicate<br />
the location, nature and extent <strong>of</strong> the work proposed and<br />
show in detail that it will conform to the provisions <strong>of</strong> this<br />
Code and the FFPC, relevant laws, ordinances, rules and<br />
regulations, as determined by the Building Official and/or<br />
Fire Marshal/Fire Code Official. (see also Section 107.6).<br />
107.2.1.1 Fire protection system shop drawings. Shop<br />
drawings for the fire protection system(s) shall be submitted<br />
to indicate conformance with this Code, the<br />
FFPC and the construction documents and shall be approved<br />
prior to the start <strong>of</strong> system installation. Shop<br />
drawings shall contain all information as required by the<br />
referenced installation standards in the Fire Protection<br />
Provisions in Chapter 9 <strong>of</strong> this Code and the FFPC.<br />
107.2.2 The elevation above mean sea level (MSL) <strong>of</strong> the<br />
top <strong>of</strong> all first floors shall appear on all construction plans<br />
2010 FBC — Building 1.28<br />
Broward County Administrative Provisions