g. special occupancy requirements<br />

h. fair housing requirements<br />

11. Interior requirements shall include the following:<br />

a. interior finishes (flame spread/smoke develop)<br />

b. light and ventilation<br />

c. sanitation<br />

12. Special systems:<br />

a. elevators<br />

b. escalators<br />

c. lifts<br />

13. Swimming Pools:<br />

a. barrier requirements<br />

b. spas<br />

c. wading pools<br />

B. Electrical<br />

1. System Riser Diagram (Electrical and/or Fire)<br />

2. Services<br />

3. Short circuit analysis<br />

4. Main and distribution panelboard locations and sizes<br />

5. Protective devices and interrupting capability<br />

6. Load Calculations<br />

7. Conductor sizes (Wiring) and insulation type<br />

8. Electrical legend<br />

9. Circuitry <strong>of</strong> all outlets and devices<br />

10. Load schedule for each panel<br />

11. Wiring methods and materials, AFCIs, GFCIs<br />

12. Grounding and bonding requirements<br />

13. Smoke Detectors and Carbon Monoxide Detectors<br />

14. Instrumentation control<br />

15. Location <strong>of</strong> all electrical devices (receptacles outlets,<br />

telephone outlets, television outlet, computer outlets,<br />

switch outlets, dimmer outlets, and similar)<br />

16. Lighting fixture performance specifications and arrangements<br />

17. Location <strong>of</strong> all electrical lighting fixtures (including all<br />

emergency and exit)<br />

18. Lighting control and circuiting<br />

19. Location <strong>of</strong> all electrical equipment (water heaters,<br />

pumps, range, dryers, air handling units, air conditioning<br />

compressors, ceiling fans, and similar)<br />

20. Accessibility requirements: show/identify accessible<br />

bath<br />

21. Communications systems<br />

22. Emergency systems<br />

23. Low voltage<br />

24. Special occupancies<br />

25. Type and location <strong>of</strong> grounding electrodes<br />

26. Design flood elevation<br />

C. Gas:<br />

1. Gas piping<br />

2. Venting<br />

3. Combustion air<br />

4. Chimneys and vents<br />

5. Appliances<br />

6. Type <strong>of</strong> gas<br />

7. Fireplaces<br />

8. LP tank location<br />

9. Riser diagram/shut<strong>of</strong>fs<br />

10. Design flood elevation<br />

Broward County Board <strong>of</strong> Rules and Appeals<br />

Effective Date: March 15, 2012<br />

D. Mechanical<br />

Energy Calculations as required by Chapter 13 <strong>of</strong> this Code<br />

A complete duct layout with:<br />

1. Specified materials<br />

2. Duct sizes<br />

3. Outside air intakes/make up air<br />

4. CFM air volumes at each duct inlet and outlet<br />

5. Diffuser sizes<br />

6. Routing and location <strong>of</strong> ducts, including risers<br />

7. Thermal resistance ratings for ducts and duct insulation<br />

8. Heating, ventilation, air conditioning and refrigeration<br />

equipment, boilers and appliances, show:<br />

a. Equipment manufacturer<br />

b. Equipment model numbers<br />

c. Equipment locations<br />

d. Equipment efficiency ratings<br />

e. Equipment mounting/support details (Mechanical<br />

equipment exposed to the wind must comply with<br />

Section 301.12 <strong>of</strong> the Florida Mechanical Code)<br />

9. Ro<strong>of</strong> mounted equipment – Detail <strong>of</strong> equipment attachment<br />

to ro<strong>of</strong> stand/curb and attachment <strong>of</strong> ro<strong>of</strong><br />

stand/curb to supporting structure (Must comply with<br />

requirements <strong>of</strong> the High Velocity Hurricane Zone):<br />

a. Equipment accessibility<br />

b. Equipment capacity in tonnage and/or horsepower<br />

c. Air conditioning refrigerant type and amount <strong>of</strong> refrigerant<br />

in system (pounds)<br />

10. Fire protection assemblies and devices – Show make,<br />

model, type, location and installation details for:<br />

a. Fire dampers<br />

b. Ceiling dampers<br />

c. Smoke dampers<br />

d. Smoke detectors (duct)<br />

e. Heat detectors<br />

f. Automatic fire doors<br />

11. Exhaust systems – Show:<br />

a. Bathroom ventilation<br />

b. Kitchen equipment exhaust<br />

c. Clothes dryer exhaust<br />

d. Specialty exhaust systems<br />

e. Laboratory<br />

12. Piping – Show:<br />

a. All piping materials and sizes<br />

b. Piping locations and terminations<br />

c. Piping insulation materials and thickness<br />

13. Chimneys, fireplaces and vents – Show:<br />

a. Location<br />

b. Venting requirements<br />

c. Combustion air<br />

14. Other:<br />

a. Details for exterior ventilation devices<br />

b. Any available product specifications, and<br />

c. Product listings.<br />

15. Design flood elevation<br />

E. Plumbing<br />

1. Minimum plumbing facilities<br />

2. Fixture requirements<br />

3. Water supply piping<br />

4. Sanitary drainage<br />

5, Location <strong>of</strong> septic tanks<br />