23. Swimming Pools/Spas Inspection: First inspections to<br />
be made after excavation and installation <strong>of</strong> reinforcing<br />
steel, bonding and main drain and prior to placing <strong>of</strong><br />
concrete, gunite or shotcrete. Second inspection(s) <strong>of</strong> perimeter<br />
plumbing, pressure test, deck electrical perimeter<br />
bonding and deck structural (includes soil reports as applicable,<br />
paver type decks, special perimeter footings or<br />
deck features) are to follow after the completion <strong>of</strong> each<br />
phase. Child barrier (exit) alarms (if applicable), and<br />
yard barriers that are part <strong>of</strong> the fourth wall protection as<br />
described in Section 424.2.17 shall be completed and approved<br />
inspection prior to the swimming pool/spa being<br />
filled with water. Final zoning (if applicable) is to be<br />
completed prior to the swimming pool/spa being completed.<br />
Electrical final is to be completed prior to the<br />
swimming pool/spa being filled with water. Final structural<br />
and plumbing is to be completed after the swimming<br />
pool/spa is filled with water and the filtration system<br />
is in operation.<br />
a. Electrical inspections:<br />
(1) Bonding<br />
(2) Deck perimeter bonding<br />
(3) Final electrical (including exit alarm(s)) (if applicable)<br />
prior to the swimming pool/spa being<br />
filled with water<br />
b. Plumbing inspections:<br />
(1) Main drain(s)<br />
(2) Perimeter plumbing, pressure test and water features<br />
(3) Final plumbing (after filling <strong>of</strong> swimming<br />
pool/spa with water and the filtration system is in<br />
operation).<br />
c. Structural inspections:<br />
(1) Steel<br />
(2) Deck (includes soil reports as applicable, paver<br />
type decks, special perimeter footings or deck<br />
features)<br />
(3) Child barrier fences (if applicable) and yard barriers<br />
that are part <strong>of</strong> the fourth wall protection<br />
prior to the swimming pool/spa being filled with<br />
water<br />
(4) Final structural (after filling <strong>of</strong> the swimming<br />
pool/spa with water and the filtration system is in<br />
operation)<br />
24. Fence: Final only.<br />
B. Electrical:<br />
1. Electrical Inspection: All Underground, Slab, And<br />
Rough Electrical Installations Shall Be left uncovered<br />
and convenient for examination until Inspected and Approved<br />
by the Electrical Inspector. Electrical inspection<br />
shall be made on each <strong>of</strong> the following items:<br />
2. Temporary Electrical Service Underground Installations<br />
a. Temporary Electrical Service/Pole/Meter Can<br />
3. Underground Electrical Inspection:<br />
a. Antenna/Satellite<br />
b. Cable Television /Television<br />
c. Feeders, e.g.. Elevator<br />
d. Lightning Protection System<br />
Broward County Board <strong>of</strong> Rules and Appeals<br />
Effective Date: March 15, 2012<br />
e. Service Lateral<br />
f. Site Lighting<br />
g. Sprinkler Pump System<br />
h. Telephone<br />
i. All other Underground Electrical Installations not<br />
listed<br />
4. Slab Electrical Inspection:<br />
a. Grounding Electrode Conductor to Foundation Steel<br />
b. Ro<strong>of</strong><br />
c. Tilt Wall<br />
d. All other Slab Electrical Installations not listed<br />
5. Rough Electrical Inspection:<br />
a. Air Conditioning Ro<strong>of</strong>/Heat Pump<br />
b. Burglary Alarm/Security System/Pre-Wire<br />
c. Cable Television/Television<br />
d. Ceiling/S<strong>of</strong>fit/House Lighting<br />
e. Central Vacuum<br />
f. Computers/POS<br />
g. Energy Management System<br />
h. Fire Alarm System/ Smoke Detectors<br />
i. Intercom/Music System/Speakers<br />
j. Lightning Protection System/Surge Arrester<br />
k. Load Management Pre-Wire<br />
l. Low Voltage Systems Miscellaneous<br />
m. Medical Gas Alarm/Nurses Call/Paging System<br />
n. Meter Rooms/Electrical Equipment Enclosures<br />
o. Security Systems<br />
p. Site Lighting<br />
q. Telephone<br />
r. Uninterrupted Power Supply<br />
s. Walls<br />
t. All other Rough Electrical Installations not listed<br />
6. Electrical Service Inspection:<br />
a. Electrical Service Changes<br />
b. Electrical Service Repairs<br />
c. Electrical Service Reconnections<br />
d. Electrical Service Final Inspection<br />
7. Miscellaneous Electrical Inspection:<br />
8. Swimming Pool/Spa Electrical Inspection:<br />
a. Bonding<br />
b. Deck perimeter bonding<br />
c. Final electrical (including exit alarm(s)) (if applicable)<br />
prior to the swimming pool/spa being filled with<br />
water<br />
9. Temporary Electrical 30-Day Power for Testing<br />
Final Electrical Inspection: To be made after the building<br />
is complete, all electrical fixtures are in place and<br />
properly connected, and the structure is ready for occupancy.<br />
a. Air Conditioning Ro<strong>of</strong>/Heat Pump<br />
b. Burglary Alarm/Security System<br />
c. Cable Television/Television<br />
d. Ceiling/S<strong>of</strong>fit/House Lighting<br />
e. Central Vacuum<br />
f. Computers/POS<br />
g. Energy Management System<br />
h. Fire Alarm System/ Smoke Detectors<br />
i. Intercom/Music System/Speakers<br />
j. Lightning Protection System/Surge Arrester<br />
k. Load Management Pre-Wire<br />
2010 FBC — Building 1.36<br />
Broward County Administrative Provisions