23. Swimming Pools/Spas Inspection: First inspections to<br />

be made after excavation and installation <strong>of</strong> reinforcing<br />

steel, bonding and main drain and prior to placing <strong>of</strong><br />

concrete, gunite or shotcrete. Second inspection(s) <strong>of</strong> perimeter<br />

plumbing, pressure test, deck electrical perimeter<br />

bonding and deck structural (includes soil reports as applicable,<br />

paver type decks, special perimeter footings or<br />

deck features) are to follow after the completion <strong>of</strong> each<br />

phase. Child barrier (exit) alarms (if applicable), and<br />

yard barriers that are part <strong>of</strong> the fourth wall protection as<br />

described in Section 424.2.17 shall be completed and approved<br />

inspection prior to the swimming pool/spa being<br />

filled with water. Final zoning (if applicable) is to be<br />

completed prior to the swimming pool/spa being completed.<br />

Electrical final is to be completed prior to the<br />

swimming pool/spa being filled with water. Final structural<br />

and plumbing is to be completed after the swimming<br />

pool/spa is filled with water and the filtration system<br />

is in operation.<br />

a. Electrical inspections:<br />

(1) Bonding<br />

(2) Deck perimeter bonding<br />

(3) Final electrical (including exit alarm(s)) (if applicable)<br />

prior to the swimming pool/spa being<br />

filled with water<br />

b. Plumbing inspections:<br />

(1) Main drain(s)<br />

(2) Perimeter plumbing, pressure test and water features<br />

(3) Final plumbing (after filling <strong>of</strong> swimming<br />

pool/spa with water and the filtration system is in<br />

operation).<br />

c. Structural inspections:<br />

(1) Steel<br />

(2) Deck (includes soil reports as applicable, paver<br />

type decks, special perimeter footings or deck<br />

features)<br />

(3) Child barrier fences (if applicable) and yard barriers<br />

that are part <strong>of</strong> the fourth wall protection<br />

prior to the swimming pool/spa being filled with<br />

water<br />

(4) Final structural (after filling <strong>of</strong> the swimming<br />

pool/spa with water and the filtration system is in<br />

operation)<br />

24. Fence: Final only.<br />

B. Electrical:<br />

1. Electrical Inspection: All Underground, Slab, And<br />

Rough Electrical Installations Shall Be left uncovered<br />

and convenient for examination until Inspected and Approved<br />

by the Electrical Inspector. Electrical inspection<br />

shall be made on each <strong>of</strong> the following items:<br />

2. Temporary Electrical Service Underground Installations<br />

a. Temporary Electrical Service/Pole/Meter Can<br />

3. Underground Electrical Inspection:<br />

a. Antenna/Satellite<br />

b. Cable Television /Television<br />

c. Feeders, e.g.. Elevator<br />

d. Lightning Protection System<br />

Broward County Board <strong>of</strong> Rules and Appeals<br />

Effective Date: March 15, 2012<br />

e. Service Lateral<br />

f. Site Lighting<br />

g. Sprinkler Pump System<br />

h. Telephone<br />

i. All other Underground Electrical Installations not<br />

listed<br />

4. Slab Electrical Inspection:<br />

a. Grounding Electrode Conductor to Foundation Steel<br />

b. Ro<strong>of</strong><br />

c. Tilt Wall<br />

d. All other Slab Electrical Installations not listed<br />

5. Rough Electrical Inspection:<br />

a. Air Conditioning Ro<strong>of</strong>/Heat Pump<br />

b. Burglary Alarm/Security System/Pre-Wire<br />

c. Cable Television/Television<br />

d. Ceiling/S<strong>of</strong>fit/House Lighting<br />

e. Central Vacuum<br />

f. Computers/POS<br />

g. Energy Management System<br />

h. Fire Alarm System/ Smoke Detectors<br />

i. Intercom/Music System/Speakers<br />

j. Lightning Protection System/Surge Arrester<br />

k. Load Management Pre-Wire<br />

l. Low Voltage Systems Miscellaneous<br />

m. Medical Gas Alarm/Nurses Call/Paging System<br />

n. Meter Rooms/Electrical Equipment Enclosures<br />

o. Security Systems<br />

p. Site Lighting<br />

q. Telephone<br />

r. Uninterrupted Power Supply<br />

s. Walls<br />

t. All other Rough Electrical Installations not listed<br />

6. Electrical Service Inspection:<br />

a. Electrical Service Changes<br />

b. Electrical Service Repairs<br />

c. Electrical Service Reconnections<br />

d. Electrical Service Final Inspection<br />

7. Miscellaneous Electrical Inspection:<br />

8. Swimming Pool/Spa Electrical Inspection:<br />

a. Bonding<br />

b. Deck perimeter bonding<br />

c. Final electrical (including exit alarm(s)) (if applicable)<br />

prior to the swimming pool/spa being filled with<br />

water<br />

9. Temporary Electrical 30-Day Power for Testing<br />

Final Electrical Inspection: To be made after the building<br />

is complete, all electrical fixtures are in place and<br />

properly connected, and the structure is ready for occupancy.<br />

a. Air Conditioning Ro<strong>of</strong>/Heat Pump<br />

b. Burglary Alarm/Security System<br />

c. Cable Television/Television<br />

d. Ceiling/S<strong>of</strong>fit/House Lighting<br />

e. Central Vacuum<br />

f. Computers/POS<br />

g. Energy Management System<br />

h. Fire Alarm System/ Smoke Detectors<br />

i. Intercom/Music System/Speakers<br />

j. Lightning Protection System/Surge Arrester<br />

k. Load Management Pre-Wire<br />

2010 FBC — Building 1.36<br />

Broward County Administrative Provisions