Snap-Action Switches Detection Switches General Catalogue 2005
Snap-Action Switches Detection Switches General Catalogue 2005
Snap-Action Switches Detection Switches General Catalogue 2005
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
2) Side COM terminal<br />
Pin plunger<br />
Actuator<br />
Short hinge lever<br />
Hinge lever<br />
Long hinge lever<br />
Simulated roller lever<br />
Short roller lever<br />
Roller lever<br />
Operating force, Max.<br />
Contact arrangement<br />
Remarks: 1. When ordering agency standard approved types, please attach the following number to the part number.<br />
9: UL/CSA 6 × 10 3 rated<br />
4: UL/CSA 10 5 rated<br />
3: UL/CSA 6 × 10 3 rated, VDE and SEMKO approved<br />
31: UL/CSA 10 5 rated, VDE and SEMKO approved<br />
8: VDE and SEMKO approved<br />
2. * is a custom ordered product. Please consult us.<br />
DATA<br />
Gold-clad type<br />
Range of low-level current voltage<br />
Contact arrangement<br />
SPDT SPST-NC SPST-NO<br />
*2.94 N AM52140D6 AM52150D6 AM52160D6<br />
3.92 N AM52140D7 AM52150D7 AM52160D7<br />
*3.14 N AM52141D6 AM52151D6 AM52161D6<br />
4.12 N AM52141D7 AM52151D7 AM52161D7<br />
*1.77 N AM52142D6 AM52152D6 AM52162D6<br />
2.35 N AM52142D7 AM52152D7 AM52162D7<br />
*0.88 N AM52143D6 AM52153D6 AM52163D6<br />
1.18 N AM52143D7 AM52153D7 AM52163D7<br />
*1.77 N AM52144D6 AM52154D6 AM52164D6<br />
2.35 N AM52144D7 AM52154D7 AM52164D7<br />
*3.14 N AM52145D6 AM52155D6 AM52165D6<br />
4.12 N AM52145D7 AM52155D7 AM52165D7<br />
*1.77 N AM52146D6 AM52156D6 AM52166D6<br />
2.35 N AM52146D7 AM52156D7 AM52166D7<br />
AM5<br />
500<br />
Current (mA)<br />
100<br />
50<br />
10<br />
5<br />
2<br />
1<br />
4 8 12 16 20 24<br />
DC voltage (V)<br />
SPECIFICATIONS<br />
1. Contact rating<br />
Gold clad contact<br />
Silver alloy contact<br />
Type<br />
0.1A type<br />
6A type<br />
11A type<br />
16A type<br />
21A type<br />
Gold clad contact for low level circuit<br />
Voltage<br />
Remark: The inductive load for DC should have a time constant of 7 ms or less.<br />
Resistive load<br />
(cos φ ] 1)<br />
Inductive load<br />
(cos φ ] 0.6 to 0.7)<br />
250V AC 0.1A 0.1A<br />
125V AC 0.1A 0.1A<br />
30V DC 0.1A 0.1A<br />
250V AC 6A 3A<br />
125V AC 6A 3A<br />
125V DC 0.5A 0.5A<br />
250V AC 11A 6A<br />
125V AC 11A 6A<br />
125V DC 0.6A 0.6A<br />
250V AC 16A 10A<br />
125V AC 16A 10A<br />
125V DC 0.6A 0.6A<br />
250V AC 21A 16A<br />
125V AC 21A 16A<br />
125V DC 0.6A 0.6A<br />
6V DC 5mA —<br />
12V DC 2mA —<br />
24V DC 1mA —<br />
67