3rd)<br />

Gantry Sign Lighting Requirements<br />

- The gantry sign lighting shall be as per CIE No. 35 (TC-4.6) 1978,<br />

and shall have a maintained average luminance of 180 candelas per<br />

square meter (for white letters) and the ratio of the maximum<br />

luminance of one color in a specified area to the minimum<br />

luminance in the same area shall not exceed:<br />

2.5 for the inner zone of each area with a definite color;<br />

5 for the outer zone of each area with a color; and<br />

8 over the total area of the sign face.<br />

Whereas the inner area shall be that area bounded by a similar rectangle of length<br />

and height equal to 70% of the overall length and height of the rectangular area<br />

located symmetrically within the sign.<br />

- The maintained average luminance value are to be based upon the<br />

total of lantern dirt depreciation factor and a lamp lumen<br />

depreciation factor of 0.65.<br />

17.11 Lamps<br />

The lamps required shall comply with the following:<br />

Table 10.11.1<br />

Street Lighting Lamps<br />

Type<br />

-High Pressure<br />

Mercury<br />

Vapour<br />

Power into<br />

Lamp (Watt)<br />

125<br />

250<br />

400<br />

Total Luminous<br />

Flux (lm)<br />

6,400<br />

15,500<br />

23,000<br />

Lamp<br />

Base<br />

E27<br />

E40<br />

E40<br />

Life Time<br />

(Min. Values)<br />

16,000<br />

16,000<br />

16,000<br />

High Pressure<br />

Sodium<br />

Rapid<br />

Start<br />

HG<br />

TLD<br />

Tube<br />

Light<br />

70<br />

150<br />

250<br />

400<br />

1000<br />

7,000<br />

16,000<br />

27,000<br />

48,000<br />

130,000<br />

E27<br />

E40<br />

E40<br />

E40<br />

E40<br />

24,000<br />

24,000<br />

24,000<br />

24,000<br />

24,000<br />

58 5,200 G13 12,000<br />

Remarks:<br />

1. The high pressure mercury vapor lamps shall be milky white color.<br />

2. The high pressure sodium lamps shall be clean tubular type and golden<br />

color.<br />

221