Emergency Oil Pump (DC)-1 no<br />

Pump Type -200/90<br />

Capacity = 108 m 3 /Hr<br />

Head 22 m <strong>of</strong> water column<br />

Motor<br />

Power 13 KW<br />

Voltage 220 V<br />

RPM 1500<br />

Current 67.6 Amps<br />

2.6.6 Condensate water system<br />

2.6.7 Deaerator:<br />

Condensate water from condenser hot well delivered through 3 vertical type<br />

condensate pumps( 2 running 1 standby) to De-aerator. <strong>Tender</strong>er have to<br />

renovate all condensate pumps including its accessories and associated pipe<br />

lines <strong>for</strong> full operation.<br />

Description <strong>of</strong> Condensate Pump-3 nos(150%)<br />

Pump Type KCB-320x160<br />

Capacity 320 m 3 /Hr<br />

Head 160 m <strong>of</strong> water column<br />

Rotational speed 1480 RPM<br />

Shaft power 174 KW<br />

Motor<br />

Power 250 KW, Power factor=0.85<br />

Voltage 6.6 KV, 50 Hz, 3 Phase<br />

Current 275 Amps<br />

RPM 1500<br />

Description <strong>of</strong> Drip Pump (Drain Pump <strong>for</strong> LP Condensate)-2 nos (200%)<br />

Pump Type Kc-80-155/3<br />

Capacity 80 m 3 /Hr<br />

Head 155 m <strong>of</strong> water column<br />

Rotational speed 2950 RPM<br />

Motor<br />

Power 75 KW<br />

Voltage 230/400 (∆Y), 50 Hz<br />

Current 227/132 Amps<br />

RPM 2950<br />

Description <strong>of</strong> Deaerator:<br />

Type DCP-1000-100<br />

100 M 3 deaerator tank<br />

Deaeration <strong>of</strong> water 1000 t/hr<br />

Remove gases from feed water.<br />

Pressure <strong>of</strong> deaerator 7 ata<br />

2.6.8 Heater (L.P, I.P, H.P)<br />

Turbine has 4 nos LP heater <strong>for</strong> heating condensate and 3 nos HP heater <strong>for</strong><br />

heating feed water<br />

Re-Powering <strong>Ghorasal</strong> 210 MW 3 rd <strong>Unit</strong> (Vol-2A <strong>of</strong> 2) 16