2.6.11 Valves<br />

2.6.12 Generator<br />

Delivery pressure 1.61-2.13 kg/cm 2<br />

RPM 485<br />

Steam turbine controlled by main stop valves, regulating valves etc. different<br />

type valves associated with steam turbine <strong>for</strong> different operation. <strong>Tender</strong>er<br />

have to renovate or replace all required valves including its operating mechanism<br />

<strong>for</strong> full operation.<br />

Generator connected with turbine in a single shaft. <strong>Tender</strong>er have to renovate<br />

steam Generator including its accessories <strong>for</strong> full operation.<br />

Steam turbine generator Description:<br />

Type TΓB-200 MT3<br />

Power - 247 MVA<br />

Active power- 210 MW<br />

Power factor- 0.85<br />

Speed <strong>of</strong> rotation - 3000 RPM<br />

Frequency- 50 Hzs<br />

No <strong>of</strong> phases 3<br />

Phase connection (Y) star<br />

Efficiency 98.45%<br />

Stator voltage- 15.75 KV ± 5%<br />

Stator Current- 9060 A<br />

Rotor Current(estimated)- 1950 A<br />

Excitation voltage 430 V<br />

Hydrogen pressure 3 Kg/cm 2<br />

H 2 purity- 98 %<br />

Static over load 1.71<br />

Short ckt ratio 0.52<br />

Main Characteristics <strong>of</strong> Cooling Media<br />

Hydrogen gas<br />

H 2 pressure -3 Kg/cm 2 ±0.2<br />

H 2 purity- not less than 97 %<br />

H 2 Temperature at cooler outlet 41 0 C<br />

Water inlet <strong>of</strong> gas cooler<br />

Flow rate 400 m 3 /Hr<br />

Temperature <strong>of</strong> cooling water=34 0 C<br />

Pressure <strong>of</strong> cooling water 3.5 Kg/cm 2<br />

Water pressure loss in gas cooler 0.8 Kg/cm 2<br />

Cooling water <strong>for</strong> stator winding 1 st ckt (Technical)<br />

Flow rate 200 m 3 /Hr<br />

Temperature <strong>of</strong> cooling water= 34 0 C<br />

Pressure <strong>of</strong> cooling water not more than 6 Kg/cm 2<br />

Cooling water <strong>for</strong> stator winding(distillate)<br />

Flow rate 45±4<br />

m 3 /Hr<br />

Temperature <strong>of</strong> cooling water=41 0 C<br />

Pressure <strong>of</strong> cooling water inlet 2.8 Kg/cm 2<br />

Pressure <strong>of</strong> cooling water outlet 0.5 -1 Kg/cm 2<br />

Electrical resistivity <strong>of</strong> distillate 75 KΩ or more<br />

at 41 0 C<br />