Introduction<br />

Firewall System Selector<br />

Construction Fire resistance Insulation Exposed Boundary CP&P WFRC*<br />

Firewall System Orientation Type period (stability criteria face distance drawing certificate<br />

<strong>and</strong> integrity (mins.) No. No.<br />

-hours)<br />

Rockfibre Trinsul Vertical Outside rail 4 60 Either within 1m T1155 C127164<br />

Firewall<br />

face<br />

Double Skin Firewall<br />

with Instaloc 40 Vertical Outside rail 4 15 Inside 1m or T1007 C107677<br />

Spacer System & face more<br />

Glassfibre Quilt<br />

Double Skin Firewall<br />

with Instaloc 40 Vertical Outside rail 4 15 Inside 1m or T1014 C107675<br />

Spacer System & face more<br />

Rockfibre Quilt<br />

Double Skin Firewall<br />

with Instaloc 40 Vertical Outside rail 4 30 Inside 1m or – 141917<br />

Spacer System & face more<br />

Rockfibre Quilts<br />

Paramount Systems Vertical Outside rail 4 30 Inside 1m or – 131145<br />

face more<br />

Structural Liner Tray Vertical Liner Tray 4 15 Inside 1m or T1150 C54353<br />

Firewall face more<br />

Structural Liner Tray Vertical Liner Tray 4 60 Either Within T1151 C80289<br />

Firewall face 1m<br />

Double Skin Firewall Horizontal Inside rail 4 15 Inside 1m or T1003 C107659<br />

Quilt Insulated face more<br />

Double Skin Firewall Vertical Inside rail 4 30 Either Within T1170 C52869<br />

Quilt Insulated face 1m<br />