Introduction<br />
Firewall System Selector<br />
Construction Fire resistance Insulation Exposed Boundary CP&P WFRC*<br />
Firewall System Orientation Type period (stability criteria face distance drawing certificate<br />
<strong>and</strong> integrity (mins.) No. No.<br />
-hours)<br />
Rockfibre Trinsul Vertical Outside rail 4 60 Either within 1m T1155 C127164<br />
Firewall<br />
face<br />
Double Skin Firewall<br />
with Instaloc 40 Vertical Outside rail 4 15 Inside 1m or T1007 C107677<br />
Spacer System & face more<br />
Glassfibre Quilt<br />
Double Skin Firewall<br />
with Instaloc 40 Vertical Outside rail 4 15 Inside 1m or T1014 C107675<br />
Spacer System & face more<br />
Rockfibre Quilt<br />
Double Skin Firewall<br />
with Instaloc 40 Vertical Outside rail 4 30 Inside 1m or – 141917<br />
Spacer System & face more<br />
Rockfibre Quilts<br />
Paramount Systems Vertical Outside rail 4 30 Inside 1m or – 131145<br />
face more<br />
Structural Liner Tray Vertical Liner Tray 4 15 Inside 1m or T1150 C54353<br />
Firewall face more<br />
Structural Liner Tray Vertical Liner Tray 4 60 Either Within T1151 C80289<br />
Firewall face 1m<br />
Double Skin Firewall Horizontal Inside rail 4 15 Inside 1m or T1003 C107659<br />
Quilt Insulated face more<br />
Double Skin Firewall Vertical Inside rail 4 30 Either Within T1170 C52869<br />
Quilt Insulated face 1m<br />
* Warrington Fire Research Centre Limited.<br />
Firewall Systems 17