Acoustic Systems<br />

Sound Reduction<br />

Structural Liner Tray System SAR8-SLT<br />

Test reference AT/92/07.<br />

Sound Reduction<br />

Graph: R w 44 dB<br />

Average SRI: R w 39.7 dB<br />

Sound Reduction Index (dB)<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

AT 92/07 (1/3 Octave)<br />

0 50 Frequency(Hz) 10000<br />

Insulation<br />

80mm rockfibre insulation.<br />

23kg/m 3 density.<br />

Liner tray<br />

HL600/130 structural liner tray 1.00mm<br />

thick.<br />

Cold bridge barrier<br />

50 x 12mm rockfibre Strip.<br />

(350Kg/m 3 density).<br />

Outer Cladding<br />

1000/32 reversed external sheet, 0.55mm<br />

thick laid horizontally.<br />

Refer to tables on pages 32 <strong>and</strong> 33 for<br />

sound absorption <strong>and</strong> reduction axis<br />

incremental frequencies<br />

Suitable for low humidity buildings.<br />

For high humidity buildings contact<br />

our Technical Department.<br />

The Building Regulations 2000<br />

Approved Document L2 – April 2002<br />

Contact our Technical Department for<br />

information on the insulation thickness<br />

needed for this system to meet part L<br />

requirements.<br />

Acoustic Systems 35