Roof and Wall - Lane Roofing
Roof and Wall - Lane Roofing
Roof and Wall - Lane Roofing
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Acoustic Systems<br />
Sound Reduction<br />
Structural Liner Tray System SAR8-SLT<br />
Test reference AT/92/07.<br />
Sound Reduction<br />
Graph: R w 44 dB<br />
Average SRI: R w 39.7 dB<br />
Sound Reduction Index (dB)<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
AT 92/07 (1/3 Octave)<br />
0 50 Frequency(Hz) 10000<br />
Insulation<br />
80mm rockfibre insulation.<br />
23kg/m 3 density.<br />
Liner tray<br />
HL600/130 structural liner tray 1.00mm<br />
thick.<br />
Cold bridge barrier<br />
50 x 12mm rockfibre Strip.<br />
(350Kg/m 3 density).<br />
Outer Cladding<br />
1000/32 reversed external sheet, 0.55mm<br />
thick laid horizontally.<br />
Refer to tables on pages 32 <strong>and</strong> 33 for<br />
sound absorption <strong>and</strong> reduction axis<br />
incremental frequencies<br />
Suitable for low humidity buildings.<br />
For high humidity buildings contact<br />
our Technical Department.<br />
The Building Regulations 2000<br />
Approved Document L2 – April 2002<br />
Contact our Technical Department for<br />
information on the insulation thickness<br />
needed for this system to meet part L<br />
requirements.<br />
Acoustic Systems 35