Acoustic Systems<br />

Sound Reduction <strong>and</strong> Absorption<br />

Paramount System<br />

Test reference AT/94/19(20) System 4.<br />

Weighted SRI, R w 30.3 dB (predicted)<br />

Insulation<br />

80mm rockfibre insulation.<br />

24kg/m 3 density.<br />

Sound Absorption Coefficient<br />

1.0<br />

0.8<br />

0.6<br />

0.4<br />

AT 94/20 System 4 (1/3 Octave)<br />

0.2<br />

100 5000<br />

Frequency(Hz)<br />

Sheeting Rail<br />

Sheeting rails supplied by others.<br />

Spacer<br />

80mm deep spacer system.<br />

Outer Cladding<br />

Trisomet Composite panel, 40mm thick,<br />

(PIR core) 1000mm cover width, laid<br />

vertically.<br />

Lining Panel<br />

Perforated LP1000 lining panel,<br />

0.4mm thick.<br />

Refer to tables on page 32 <strong>and</strong> 33 for axis<br />

increment frequencies<br />

‘U’ Value for this system is 0.24W/m 2 K.<br />

Suitable for low humidity buildings.<br />

For high humidity buildings contact<br />

our Technical Department.<br />

Acoustic Systems 33