St<strong>and</strong>ard <strong>Wall</strong> Profile Range<br />
Material<br />
Gauge (mm)<br />
Weight (kg/m 2 )<br />
Load/Span –<br />
max span (mm) SS<br />
Load/Span –<br />
max span (mm) MS<br />
Minimum<br />
self curve (m)<br />
Minimum<br />
factory curve (mm)<br />
Suitable for<br />
Horizontal use<br />
C13.5/3 S 0.5 4.86 1200 1400 20 (h), 30 (p), 35 (mp) 1000* N<br />
0.7 6.79 1300 1600 20 (h), 30 (p), 35 (mp) 1000* Y<br />
A 0.9 3.05 1100 1400 20 (sa/ca), 25 (mp) 1000* Y<br />
C19 S 0.5 4.52 1400 1500 20 (h), 30 (p), 35 (mp) 350 N<br />
0.7 6.75 1500 1900 20 (h), 30 (p), 35 (mp) 350 Y<br />
A 0.9 3.02 1200 1500 20 (sa/ca), 25 (ma) 350 Y<br />
C32/1000 S 0.5 4.82 1800 1800 40 (h), 50 (p), 55 (mp) 400 N<br />
0.7 6.75 2100 2500 40 (h), 50 (p), 55 (mp) 400 Y<br />
A 0.9 3.02 1700 2100 40 (sa/ca), 45 (ma) 400 Y<br />
C32S S 0.5 5.02 2100 1900 40 (h), 50 (p), 55 (mp) NA N<br />
0.7 7.01 2300 2800 40 (h), 50 (p), 55 (mp) NA Y<br />
A 0.9 3.15 1800 2200 40 (sa/ca), 45 (ma) NA Y<br />
C35A S 0.5 5.35 2200 2100 40 (h), 50 (p), 55 (mp) 400 N<br />
0.7 7.2 2500 2900 40 (h), 50 (p), 55 (mp) 400 Y<br />
A 0.9 3.05 2000 2400 40 (sa/ca), 45 (ma) 400 Y<br />
Key<br />
S – Steel<br />
A – Aluminium<br />
h – HPS200 ® by Corus<br />
p – Colorcoat ® PVDF<br />
mp – Metallic PVDF/Celestia ®<br />
by Corus<br />
sa – Stucco embossed<br />
aluminium<br />
ca – Coated aluminium<br />
ma – Metallic coated<br />
aluminium<br />
SS – Single span<br />
MS – Multi span<br />
Before ordering it is important<br />
to confirm with Corus Panels<br />
<strong>and</strong> Profiles which side of the<br />
profile carries the main surface<br />
finish.<br />
All profiles comply to current<br />
MCRMA Tolerances.<br />
* Factory curve only applies to<br />
980 cover R13.5/3.<br />
C38A S 0.7 7.38 2500 3000 40 (h), 50 (p), 55 (mp) 400 Y<br />
A 0.9 3.31 2000 2400 40 (sa/ca), 45 (ma) 400 Y<br />
C46 S 0.5 5.35 2800 2200 55 (h), 65 (p), 70 (mp) 400 N<br />
0.7 7.5 3100 3600 55 (h), 65 (p), 70 (mp) 400 Y<br />
A 0.9 3.36 2400 3000 55 (sa/ca), 60 (ma) 400 Y<br />
C60 S 0.5 6.03 3400 2600 70 (h), 80 (p), 85 (mp) NA N<br />
0.7 8.44 3900 4000 70 (h), 80 (p), 85 (mp) NA Y<br />
A 0.9 3.78 3000 3700 70 (sa/ca), 75 (ma) NA Y<br />
WP40 S 0.7 7.50 2000 2200 60 (h), 70 (p), 75 (mp) 400 N<br />
A 0.9 3.36 1700 2000 60 (sa/ca), 65 (h) 400 N<br />
Suncrest Surrounds Ltd., Co.Durham.<br />
<strong>Roof</strong> & <strong>Wall</strong>- Site Assembled Systems 7