Acoustic Systems<br />
Sound Reduction Index<br />
Measurement (1/3 octave)<br />
Sound Absorption Index<br />
Measurement (1/3 octave)<br />
Frequency SR3-LP LPC Paramount SAR8-SLT<br />
(Hz) C/95/5L/1721/1 System* AT/92/07<br />
Test 1<br />
50 13.9 23.4<br />
63 10.8 17.6<br />
80 6.5 23.2<br />
100 12.2 12.2 22.2<br />
125 16.4 14.0 27.5<br />
160 19.9 15.8 27.9<br />
200 23.2 17.4 32.4<br />
250 31.0 19.2 35.2<br />
315 36.1 21.2 37.0<br />
400 40.5 23.2 40.2<br />
500 43.4 25.3 41.4<br />
630 46.4 27.6 43.1<br />
800 48.4 30.2 42.9<br />
1000 51.7 32.8 45.1<br />
1250 51.4 35.7 45.6<br />
1600 52.6 39.2 47.5<br />
2000 53.0 42.6 47.3<br />
2500 52.5 46.2 49.4<br />
3150 55.8 50.0 50.1<br />
4000 59.5 53.4 51.4<br />
5000 61.3 53.7 52.7<br />
6300 60.3 54.8<br />
8000 60.6 55.5<br />
10000 56.5 54.3<br />
Frequency SAR4-SLT LPC Paramount<br />
(Hz) AT/92/07 System<br />
System 2<br />
50<br />
63<br />
80<br />
100 0.38 0.24<br />
125 0.57 0.47<br />
160 0.53 0.41<br />
200 0.65 0.47<br />
250 0.64 0.53<br />
315 0.79 0.68<br />
400 0.76 0.82<br />
500 0.74 0.84<br />
630 0.77 0.82<br />
800 0.81 0.81<br />
1000 0.81 0.81<br />
1250 0.82 0.76<br />
1600 0.84 0.77<br />
2000 0.87 0.79<br />
2500 0.89 0.80<br />
3150 1.02 0.79<br />
4000 1.01 0.85<br />
5000 1.23 1.00<br />
6300<br />
8000<br />
Average SRI (dB) 39.7 31.0<br />
Weighted SRI (dB) 39 30.3<br />
* Predicted Results<br />
Extensive range of systems<br />
Acoustic Systems 31