4 Hour<br />
1 Hour Insulation 4 Hour Integrity<br />
Rockfibre Trinsul Firewall (vertical outside rail)<br />
Corus Panels <strong>and</strong> Profiles Rockfibre<br />
Trinsul outside rail cladding system<br />
has a 1 hour fire resistance from<br />
either direction when fixed within<br />
1 metre of relevant boundary.<br />
Insulation<br />
80kg/m 3 nominal density profiled<br />
rockfibre trinsul insulation board.<br />
Minimum thickness to achieve<br />
0.35W/m 2 K ‘U’ value.<br />
Lining Panel<br />
Corus Panels <strong>and</strong> Profiles colorcoated<br />
galvanised steel 0.4/0.7mm thick.<br />
Sheeting Rail<br />
Sheeting rails supplied by others.<br />
The rail is not fire protected but a facility<br />
for expansion is required (slotted fixing<br />
holes).<br />
LPC<br />
Rockfibre Trinsul meets fully the<br />
requirements of part 2.2 of the LPC<br />
design guide for the fire protection of<br />
buildings 2000.<br />
Outer Cladding<br />
Corus Panels <strong>and</strong> Profiles colorcoated<br />
galvanised steel 0.5/0.7mm thick.<br />
Construction Notes<br />
All fixings <strong>and</strong> components to be steel.<br />
All outer sheet side laps must be stitched<br />
at not more than 400mm centres.<br />
Lining panel does not require stitching.<br />
Warrington Fire Research Centre number<br />
C127164.<br />
The Building Regulations 2000<br />
Approved Document L2 – April 2002<br />
Contact Corus Panels <strong>and</strong> Profiles<br />
Technical Department for information on<br />
the insulation thickness needed for this<br />
system to meet part L requirements.<br />
18 Firewall Systems