High-efficiency steel boilers<br />

•MINIA CB<br />

– High-efficiency proof steel boilers for hot sanitary water heating supply,<br />

ideal for domestic heating.<br />

- Ultra thick steel boiler shell.<br />

- 120 Lt. storage boiler in painted steel for big amounts of hot sanitary<br />

water.<br />

- 12 Lt. expansion tank for heating circuit.<br />

- Sanitary and heating circuit circulators.<br />

- Stainless steel turbolators.<br />

- IPX4D protection degree.<br />

• Pre-assembled and pre-calibrated burner fitted with<br />

external air intake<br />

– Two-valve gas burner, stabilizer, filter, gas and air pressure switch for<br />

minimum pressure.<br />

- High-performance cone-shaped light oil burner.<br />

• Electronic control panel featuring the following<br />

functions:<br />

– Heating temperature regulation through display (hot sanitary water/<br />

heating).<br />

- Time and date schedule of daily and weekly operation intervals for<br />

heating and sanitary circuits.<br />

- Multifunction LCD display and relevant digital controls.<br />

- Reckoning of the operation hours.<br />

- CHECK CONTROL function for self-diagnosis.<br />

- Circulator antiscuff (once every 170 hours).<br />

- “Antilegionella” function (once every 168 hours with the boiler<br />

temperature amounting to 60°C).<br />

- Summer/Winter/Manual/Stand-by operational conditions.<br />

• Installation and Maintenance<br />

– Maintenance is made simple thanks to easy accessibility to internal<br />

components.<br />

- Installation is enabled by the burner pre-assembly.<br />

• Optional accessories<br />

– For optional accessories intended for MINIA CB boilers<br />

see page 85.<br />

– External probe allowing variable temperature management<br />

within the operation range intended for the boiler.<br />

– Room thermostat or “remote” control with/without<br />

external probe.<br />

– “Multizone” card for managing up to 4 direct zones or up to<br />

2 direct and 1 mixed zone, with/without external probe.<br />

• Certification<br />

– MINIA CB boilers are EC type approved.<br />

1330<br />

600 150 600<br />

1<br />

a2<br />

2<br />

a2<br />

3<br />

a2<br />

a7<br />

a8<br />

a5<br />

a1<br />

a4<br />

a3 1<br />

a3 2<br />

a3 3<br />

a6<br />

179<br />

Ø100<br />

1240<br />

Boiler Furnace Useful Maximum Power Hot sanitary water Heating Heating Air Cold water Hot water Burner Light oil Gas Weight<br />

type power efficiency % heating voltage production ΔT 30°C delivery return change inlet outlet suction unit connection connection<br />

kW kcal/h 100 % 30 % pressure V/Hz l/h Ø a2 Ø a3 Ø a4 Ø a6 Ø a5 Ø a1 Ø a7 Ø a8 kg<br />

MINIA 31 CB 33,9 29.154 90,26 91,02 3 6 230/50 765 3/4” 3/4” 3/4” 3/4” 3/4” 80 3/4” 3/8” 202<br />

Boiler<br />

Useful power<br />

type kW kcal/h<br />

MINIA 31 CB 30,5 26.230<br />

13