High efficiency cast iron boiler<br />

•“proof” BIA F<br />

- Proof basement boilers suitable for hot sanitary water heating and supply.<br />

- Cast iron boiler shell.<br />

- Combustion chamber and exchanger being designed for over 90%<br />

guaranteed efficiency.<br />

- Stainless steel boiler, covered with high-density polystyrene: 90 Lt. for<br />

model BIA 30-90 and 120 Lt. for model BIA 40-120.<br />

- Burner fitted with external air inlet.<br />

- Heating circuit 10 Lt. expansion tank.<br />

- Sanitary circuit 4 Lt. expansion tank.<br />

- Heating and sanitary circuit circulators.<br />

- IP X4D protection degree.<br />

• Pre-assembled and pre-calibrated air inlet burner<br />

- Two-valve gas burner, stabilizer, filter, gas and air pressure switch for<br />

minimum pressure.<br />

- High-performance cone-shaped light oil burner, complete with nozzle<br />

pre-heater.<br />

• Electronic control panel featuring the following<br />

functions:<br />

- Heating and sanitary temperature regulation.<br />

- Defect display.<br />

- Anti-freeze function.<br />

- Post-circulation function.<br />

- “antilegionella” function.<br />

• Installation and Maintenance<br />

- A burner can be fitted onto the boiler plate.<br />

- Maintenance is made simple thanks to easy accessibility to internal<br />

components.<br />

• Certification<br />

- BIA F boilers are EC type approved.<br />

Gas thermal couplings are supplied on demand. Please contact<br />

our Sales Department to be informed on the delivery time.<br />

a1<br />

Ø 130<br />

a1<br />

Ø 130<br />

a6<br />

a6<br />

1400<br />

a2<br />

a3<br />

a5<br />

a4<br />

1037<br />

1400<br />

a2<br />

a3<br />

a5<br />

a4<br />

1037<br />

500 706<br />

500 906<br />

BIA F 30-90 BIA F 40-120<br />

boiler furnace useful maximum power hot sanitary water heating heating boiler boiler hot water tank burner weight<br />

type power efficiency % pressure bar voltage supply ΔT 30°C delivery return delivery return ricirculation suction unit<br />

kW kcal/h 100 % 30 % risc. sanit. V/Hz l/h Ø a1 Ø a2 Ø a3 Ø a4 Ø a5 Ø a6 kg<br />

BIA F 30-90 34 29.240 90 92 3 7 230/50 800 1” 1” 3/4” 3/4” 3/4” 80 180<br />

BIA F 40-120 51,4 44.204 90,4 92,14 3 7 230/50 900 1” 1” 3/4” 3/4” 3/4” 80 240<br />

boiler<br />

useful power<br />

type kW kcal/h<br />

BIA F 30-90 30,6 26.316<br />

BIA F 40-120 46,5 39.990<br />

25