CALORECLIMA<br />

Wall-hung indoor gas boilers<br />

•“wall-hung boiler” VELA XN<br />

- High-efficiency open (mod. MB) and proof chamber (mod. MBS)<br />

boilers suitable for hot sanitary water heating and supply.<br />

- 60 Lt. storage unit stainless steel boiler.<br />

- Copper exchanger.<br />

- Atmospheric burner, in stainless steel for all kinds of gas.<br />

- Combustion chamber provided with ceramic fibre insulation.<br />

- Ionization flame control electronic ignition.<br />

- Electronically controlled proportional modulation for heating and<br />

sanitary circuit.<br />

- Suitable for low temperature system operation.<br />

- Proof combustion circuit with flue discharge electrical fan (mod. MBS).<br />

- Safety FLUE CONTROL preventing burnt gases from entering the<br />

room (mod. MB).<br />

- Slow opening gas valve.<br />

- 8 Lt. expansion tank.<br />

- 2 Lt. sanitary circuit expansion tank.<br />

- High-prevalence circulator.<br />

- Three-way electrical valve.<br />

- Instruments for unit control and regulation.<br />

- Flue standard intake in the boiler (mod. MBS).<br />

- “antilegionella” function.<br />

- By-pass.<br />

- IP X4D protection degree.<br />

• Installation and Maintenance<br />

- Easy installation thanks to template connections and water<br />

connection kits (on demand).<br />

- Maintenance is made simple thanks to easy accessibility to internal<br />

components.<br />

A<br />

B<br />

C<br />

• Optional accessories<br />

- For accessories suitable for VELA XN boiler, see page 85.<br />

- Flue inlet/outlet kits are not included in the supply. See accessories on<br />

demand on page 85.<br />

• Certification<br />

– VELA XN boilers are EC type approved.<br />

900<br />

600 440<br />

195<br />

**<br />

122<br />

VELA XN<br />

dimensions<br />

boiler furnace power useful efficiency Maximum pressure power hot sanitary A B C Weight<br />

type % bar voltage water supply ΔT 30°C<br />

kW kcal/h 100% 30% risc. sanit. V/Hz l/min Ø mm. mm. mm. Kg<br />

VELA XN 24 MB W TOP/IT 26 22.360 90 86,8 3 8 230/50 11,2 132,5 130 220 64<br />

VELA XN 24 MBS W TOP/IT 26 22.360 92 88,7 3 8 230/50 11,4 * 94,5 222 69<br />

* Flue connections: concentric or split discharge - ** Air suction Ø80.<br />

boiler Fuel boiler Useful power<br />

code type kW kcal/h<br />

00906240 natural gas VELA XN 24 MB W TOP/IT 10,43÷ 23,4 8.970÷ 20.124<br />

00906500 LPG VELA XN 24 MB W TOP/IT 10,43÷ 23,4 8.970÷ 20.124<br />

00906250 natural gas VELA XN 24 MBS W TOP/IT 10,5÷ 23,92 9.030÷ 20.571<br />

00906510 LPG VELA XN 24 MBS W TOP/IT 10,5÷ 23,92 9.030÷ 20.571<br />