Instantaneous gas water heaters<br />

•SIL<br />

- High-efficiency open chamber (mod. SIL 14 top) and proof (mod. SIL<br />

14S top) water heaters suitable for hot sanitary water supply.<br />

- High-efficiency copper exchanger.<br />

- Electronic ignition with ionization flame control.<br />

- Stainless steel atmospheric burner for all kinds of gas.<br />

- Proof combustion circuit with flue exhaust electrical fan (mod. S).<br />

- Continuous modulation gas valve.<br />

- Safety FLUE CONTROL preventing burnt gases from entering the<br />

room (mod. SIL TOP).<br />

- Combustion chamber provided with ceramic fibre insulation (mod. S).<br />

- Instruments for unit control and regulation.<br />

- Sanitary flow meter.<br />

- IP X4D protection degree.<br />

• Installation and Maintenance<br />

- Easy installation of the water heater thanks to template connections.<br />

- Maintenance is made simple thanks to easy accessibility to internal<br />

components.<br />

• Optional accessories<br />

- For accessories suitable for SIL water heater, see page 85.<br />

- Flue suction/exhaust kits are not included in the supply. See accessories<br />

on demand on page 85.<br />

- Polyphosphate doser type DPO/B.<br />

• Certification<br />

- SIL water heaters are EC type approved.<br />

220<br />

A 94,5<br />

- In the presence of hard water it is<br />

recommended to assemble a<br />

polyphosphate proportional doser at the<br />

water heater cold water inlet.<br />

675<br />

440<br />

250<br />

**<br />

97<br />

184,5<br />

dimensions for<br />

SIL S Top<br />

Connections: see template on page 79.<br />

water heater furnace power hot sanitary water Sanitary circuit power A Cold water Hot water gas Weight<br />

type supply (ΔT 25°C) l/min. max. pressure voltage inlet outlet inlet<br />

kW kcal/h min max bar V/Hz mm. Ø Ø Ø kg<br />

SIL 14 TOP 27 23.220 2,5 13,6 10 230/50 132,5 1/2” 1/2” 1/2” 25<br />

SIL 14 S TOP 27 23.220 2,5 13,6 10 230/50 * 1/2” 1/2” 1/2” 26<br />

* Flue connections: concentric or split discharge<br />

water heater fuel water heater Useful power<br />

code type kW kcal/h<br />

00045100 natural gas SIL 14 TOP 8÷ 23,7 6.880÷ 20.468<br />

00045110 LPG SIL 14 TOP 8÷ 23,7 6.880÷ 20.468<br />

00045120 natural gas SIL 14 S TOP 8÷ 23,7 6.880÷ 20.468<br />

00045130 LPG SIL 14 S TOP 8÷ 23,7 6.880÷ 20.468<br />