Wall-hung indoor gas boilers<br />
•“bithermal compact” XILO<br />
- Open (mod. MC) and proof chamber (mod. MCS) boilers suitable for<br />
hot sanitary water heating and supply.<br />
- Suitable for low temperature system operation.<br />
- Reduced overall dimensions (-20% if compared to the standard<br />
boilers).<br />
- High-efficiency bi-thermal copper exchanger.<br />
- Atmospheric burner, in stainless steel for all kinds of gas.<br />
- Ionization flame control electronic ignition.<br />
- Electronically controlled proportional modulation for heating and<br />
sanitary circuit.<br />
- Proof combustion circuit with flue discharge electrical fan (mod. MCS).<br />
- Safety FLUE CONTROL preventing burnt gases from entering the<br />
room (mod. MC).<br />
- Slow opening gas valve.<br />
- Combustion chamber provided with ceramic fibre insulation.<br />
- High-prevalence circulator.<br />
- 8 Lt. expansion tank.<br />
- Instruments for unit control and regulation.<br />
- Flue standard intake in the boiler (mod. MCS).<br />
- Precedence flow meter.<br />
- IP X4D protection degree.<br />
• Installation and Maintenance<br />
- Easy installation thanks to template connections and water connection<br />
kits (on demand).<br />
- Maintenance is made simple thanks to easy accessibility to internal<br />
components.<br />
220<br />
A<br />
160<br />
• Optional accessories<br />
- For accessories suitable for XILO boiler, see page 85.<br />
- Flue inlet/outlet kits are not included in the supply. See accessories on<br />
demand on page 85.<br />
- Polyphosphate doser of the DPO/B type.<br />
770<br />
• Certification<br />
- XILO boilers are EC type approved.<br />
440 330<br />
97<br />
- In the presence of hard water it is<br />
recommended to assemble a<br />
polyphosphate proportional doser at the<br />
boiler cold water inlet.<br />
250<br />
XILO MCS<br />
dimensions<br />
boiler furnace power useful efficiency Maximum pressure power hot sanitary A Weight<br />
type % bar voltage water supply ΔT 30°C<br />
kW kcal/h 100 % 30 % risc. sanit. V/Hz l/min. Ø mm kg<br />
XILO 20 MC W TOP U/IT 25 21.500 90 87,3 3 8 230/50 2,5÷ 10,8 132,5 38<br />
XILO 20 MCS W TOP U/IT 25 21.500 91 87,3 3 8 230/50 2,5÷ 11 * 40<br />
* Flue connections: concentric or split discharge<br />
boiler Fuel boiler Useful power<br />
code type kW kcal/h<br />
00902951 natural gas XILO 20 MC W TOP U/IT 8,45÷ 22,5 7.267÷ 19.350<br />
00902961 LPG XILO 20 MC W TOP U/IT 8,45÷ 22,5 7.267÷ 19.350<br />
00902604 natural gas XILO 20 MCS W TOP U/IT 8,31÷ 22,75 7.146÷ 19.565<br />
00902904 LPG XILO 20 MCS W TOP U/IT 8,31÷ 22,75 7.146÷ 19.565<br />