Wall-hung indoor gas boilers<br />

•“bithermal compact” XILO<br />

- Open (mod. MC) and proof chamber (mod. MCS) boilers suitable for<br />

hot sanitary water heating and supply.<br />

- Suitable for low temperature system operation.<br />

- Reduced overall dimensions (-20% if compared to the standard<br />

boilers).<br />

- High-efficiency bi-thermal copper exchanger.<br />

- Atmospheric burner, in stainless steel for all kinds of gas.<br />

- Ionization flame control electronic ignition.<br />

- Electronically controlled proportional modulation for heating and<br />

sanitary circuit.<br />

- Proof combustion circuit with flue discharge electrical fan (mod. MCS).<br />

- Safety FLUE CONTROL preventing burnt gases from entering the<br />

room (mod. MC).<br />

- Slow opening gas valve.<br />

- Combustion chamber provided with ceramic fibre insulation.<br />

- High-prevalence circulator.<br />

- 8 Lt. expansion tank.<br />

- Instruments for unit control and regulation.<br />

- Flue standard intake in the boiler (mod. MCS).<br />

- Precedence flow meter.<br />

- IP X4D protection degree.<br />

• Installation and Maintenance<br />

- Easy installation thanks to template connections and water connection<br />

kits (on demand).<br />

- Maintenance is made simple thanks to easy accessibility to internal<br />

components.<br />

220<br />

A<br />

160<br />

• Optional accessories<br />

- For accessories suitable for XILO boiler, see page 85.<br />

- Flue inlet/outlet kits are not included in the supply. See accessories on<br />

demand on page 85.<br />

- Polyphosphate doser of the DPO/B type.<br />

770<br />

• Certification<br />

- XILO boilers are EC type approved.<br />

440 330<br />

97<br />

- In the presence of hard water it is<br />

recommended to assemble a<br />

polyphosphate proportional doser at the<br />

boiler cold water inlet.<br />

250<br />

XILO MCS<br />

dimensions<br />

boiler furnace power useful efficiency Maximum pressure power hot sanitary A Weight<br />

type % bar voltage water supply ΔT 30°C<br />

kW kcal/h 100 % 30 % risc. sanit. V/Hz l/min. Ø mm kg<br />

XILO 20 MC W TOP U/IT 25 21.500 90 87,3 3 8 230/50 2,5÷ 10,8 132,5 38<br />

XILO 20 MCS W TOP U/IT 25 21.500 91 87,3 3 8 230/50 2,5÷ 11 * 40<br />

* Flue connections: concentric or split discharge<br />

boiler Fuel boiler Useful power<br />

code type kW kcal/h<br />

00902951 natural gas XILO 20 MC W TOP U/IT 8,45÷ 22,5 7.267÷ 19.350<br />

00902961 LPG XILO 20 MC W TOP U/IT 8,45÷ 22,5 7.267÷ 19.350<br />

00902604 natural gas XILO 20 MCS W TOP U/IT 8,31÷ 22,75 7.146÷ 19.565<br />

00902904 LPG XILO 20 MCS W TOP U/IT 8,31÷ 22,75 7.146÷ 19.565<br />