Wall-hung indoor gas boilers<br />

•XILO T<br />

- Open (mod. M) and proof chamber (mod. MS) boilers suitable for<br />

heating.<br />

- Suitable for low temperature system operation.<br />

- Reduced overall dimensions (-20% if compared to the standard<br />

boilers).<br />

- High-efficiency primary copper exchanger.<br />

- Atmospheric burner, in stainless steel for all kinds of gas.<br />

- Ionization flame control electronic ignition.<br />

- Electronically controlled proportional modulation for heating circuit.<br />

- Proof combustion circuit with flue discharge electrical fan (mod. MS).<br />

- Safety FLUE CONTROL preventing burnt gases from entering the<br />

room (mod. M).<br />

- High-prevalence circulator.<br />

- 8 Lt. expansion tank.<br />

- Slow opening gas valve.<br />

- Combustion chamber provided with ceramic fibre insulation.<br />

- Instruments for unit control and regulation.<br />

- Flue standard intake in the boiler (mod. MCS).<br />

- IP X4D protection degree.<br />

- XILO T 24 boilers can be combined with PAC B boilers.<br />

• Installation and Maintenance<br />

- Easy installation thanks to template connections and water connection<br />

kits (on demand).<br />

- Maintenance is made simple thanks to easy accessibility to internal<br />

components.<br />

220<br />

A<br />

160<br />

• Optional accessories<br />

- For accessories suitable for XILO T boiler, see page 85.<br />

- Flue inlet/outlet kits are not included in the supply. See accessories on<br />

demand on page 85.<br />

770<br />

• Certification<br />

- XILO T boilers are EC type approved.<br />

440 330<br />

97<br />

250<br />

XILO T MS<br />

dimensions<br />

boiler furnace power useful efficiency Maximum heating power voltage A Weight<br />

type % circuit pressure<br />

kW kcal/h 100 % 30 % bar V/Hz Ø mm kg<br />

XILO T 20 M W TOP U/IT 26 22.360 91 88,7 3 230/50 132,5 33<br />

XILO T 20 MS W TOP U/IT 26 22.360 91,3 89 3 230/50 * 35<br />

XILO T 24 M W TOP U/IT 30,2 25.972 91,2 90 3 230/50 152,5 34<br />

XILO T 24 MS W TOP U/IT 30,2 25.972 91 88,9 3 230/50 * 36<br />

* Flue connections: concentric or split discharge<br />

boiler Fuel boiler Useful power<br />

code type kW kcal/h<br />

00903121 natural gas XILO T 20 M W TOP U/IT 10,62÷ 23,66 9.133÷ 20.348<br />

00903131 LPG XILO T 20 M W TOP U/IT 10,62÷ 23,66 9.133÷ 20.348<br />

00903002 natural gas XILO T 20 MS W TOP U/IT 10,47÷ 23,73 9.004÷ 20.407<br />

00903012 LPG XILO T 20 MS W TOP U/IT 10,47÷ 23,73 9.004÷ 20.047<br />

00903141 natural gas XILO T 24 M W TOP U/IT 12,56÷ 27,54 10.804÷ 23.686<br />

00903151 LPG XILO T 24 M W TOP U/IT 12,56÷ 27,54 10.804÷ 23.686<br />

00903161 natural gas XILO T 24 MS W TOP U/IT 11,94÷ 27,48 10.268÷ 23.633<br />

00903171 LPG XILO T 24 MS W TOP U/IT 11,94÷ 27,48 10.268÷ 23.633<br />