Wall-hung indoor gas boilers<br />
•XILO T<br />
- Open (mod. M) and proof chamber (mod. MS) boilers suitable for<br />
heating.<br />
- Suitable for low temperature system operation.<br />
- Reduced overall dimensions (-20% if compared to the standard<br />
boilers).<br />
- High-efficiency primary copper exchanger.<br />
- Atmospheric burner, in stainless steel for all kinds of gas.<br />
- Ionization flame control electronic ignition.<br />
- Electronically controlled proportional modulation for heating circuit.<br />
- Proof combustion circuit with flue discharge electrical fan (mod. MS).<br />
- Safety FLUE CONTROL preventing burnt gases from entering the<br />
room (mod. M).<br />
- High-prevalence circulator.<br />
- 8 Lt. expansion tank.<br />
- Slow opening gas valve.<br />
- Combustion chamber provided with ceramic fibre insulation.<br />
- Instruments for unit control and regulation.<br />
- Flue standard intake in the boiler (mod. MCS).<br />
- IP X4D protection degree.<br />
- XILO T 24 boilers can be combined with PAC B boilers.<br />
• Installation and Maintenance<br />
- Easy installation thanks to template connections and water connection<br />
kits (on demand).<br />
- Maintenance is made simple thanks to easy accessibility to internal<br />
components.<br />
220<br />
A<br />
160<br />
• Optional accessories<br />
- For accessories suitable for XILO T boiler, see page 85.<br />
- Flue inlet/outlet kits are not included in the supply. See accessories on<br />
demand on page 85.<br />
770<br />
• Certification<br />
- XILO T boilers are EC type approved.<br />
440 330<br />
97<br />
250<br />
XILO T MS<br />
dimensions<br />
boiler furnace power useful efficiency Maximum heating power voltage A Weight<br />
type % circuit pressure<br />
kW kcal/h 100 % 30 % bar V/Hz Ø mm kg<br />
XILO T 20 M W TOP U/IT 26 22.360 91 88,7 3 230/50 132,5 33<br />
XILO T 20 MS W TOP U/IT 26 22.360 91,3 89 3 230/50 * 35<br />
XILO T 24 M W TOP U/IT 30,2 25.972 91,2 90 3 230/50 152,5 34<br />
XILO T 24 MS W TOP U/IT 30,2 25.972 91 88,9 3 230/50 * 36<br />
* Flue connections: concentric or split discharge<br />
boiler Fuel boiler Useful power<br />
code type kW kcal/h<br />
00903121 natural gas XILO T 20 M W TOP U/IT 10,62÷ 23,66 9.133÷ 20.348<br />
00903131 LPG XILO T 20 M W TOP U/IT 10,62÷ 23,66 9.133÷ 20.348<br />
00903002 natural gas XILO T 20 MS W TOP U/IT 10,47÷ 23,73 9.004÷ 20.407<br />
00903012 LPG XILO T 20 MS W TOP U/IT 10,47÷ 23,73 9.004÷ 20.047<br />
00903141 natural gas XILO T 24 M W TOP U/IT 12,56÷ 27,54 10.804÷ 23.686<br />
00903151 LPG XILO T 24 M W TOP U/IT 12,56÷ 27,54 10.804÷ 23.686<br />
00903161 natural gas XILO T 24 MS W TOP U/IT 11,94÷ 27,48 10.268÷ 23.633<br />
00903171 LPG XILO T 24 MS W TOP U/IT 11,94÷ 27,48 10.268÷ 23.633<br />