Aluminium radiators<br />

•Aluminium radiators<br />

- High radiant power radiators, made by high-pressure die-casting<br />

special aluminium alloy.<br />

- Thermal emission is optimized thanks to bigger convective fins with<br />

respect to wet surfaces.<br />

- Maximum operation pressure: 10 bar<br />

- Battery inspection through hydropneumatic system.<br />

- The radiators are suitable both for standard and single-pipe systems.<br />

- Fitted with 1” Ø connections allowing direct assembly of the valves in<br />

single-pipe systems.<br />

- Paint covering is protected by a thermo retractile polyethylene film.<br />

• Installation and Maintenance<br />

- Minimum distances from the wall and from the floor are approximately<br />

30 mm. and 120 mm. respectively.<br />

- In the event of under recess installation, a space of 100 mm. upwards<br />

shall be kept.<br />

- Make sure that the filling water hardness is lower than 15°F with a Ph<br />

ranging from 7 to 8.<br />

- Do not use solvents or abrasive materials when cleaning the radiator,<br />

thus avoiding to damage the paint covering.<br />

- Do not use fired tile nor porous material humidifiers.<br />

• Optional accessories<br />

- For optional accessories intended for aluminium radiators, see page?<br />

- In the presence of hard water it is<br />

recommended to assemble a<br />

polyphosphate proportional dosing unit<br />

at the boiler cold water inlet.<br />

80<br />

98<br />

A<br />

B<br />

800<br />

radiator radiator A B<br />

code type<br />

F17165100 510 500 581,5<br />

F17166100 610 500 581,5<br />

F17167100 710 500 581,5<br />

F17168100 810 500 581,5<br />

Larghezza<br />

Singolo<br />

10 elements<br />

• Technical data<br />

Types 510 610 710 810<br />

Heating power ΔT 50°C in compliance with EN 442 W 1.220 1.410 1.590 1.730<br />

kcal/h 1.049,2 1.212,6 1.367,4 1.487,8<br />

Heating power ΔT 60°C in compliance with EN 442 W 1.545 1.788 2.026 2.201<br />

Heating power ΔT 70°C in compliance with EN 442 W 1.887 2.187 2.488 2.698<br />

Heating power per part ΔT 50°C in compliance with EN 442 W 122 141 159 173<br />

kcal/h 104,92 121,26 136,74 148,78<br />

K coefficient n 1,2962 1,3039 1,3282 1,3204<br />

Maximum operation pressure bar 10 10 10 10<br />

Water composition l 4 4,3 5 5,2<br />

Elements n 10 10 10 10<br />

Connections Ø 1” 1” 1” 1”<br />

Weight kg 13 15 18 20<br />