Pre-mixed condensation gas heating modules<br />
•REPLY<br />
- Ultra-high efficiency condensation heating module, suitable for heating<br />
(Reply R) and hot sanitary water heating and supply (Reply C).<br />
- Ideal for low temperature system operation.<br />
- Special casting aluminium corrosion proofing enbloc exchangers.<br />
- Wet-type combustion chambers.<br />
- Stainless steel pre-mixing burner.<br />
- Electronically controlled continuous modulation for both heating<br />
circuits with steady air/gas ratio.<br />
- Ionization flame control electronic ignition.<br />
- Instruments for unit control and regulation.<br />
- Boiler circuit high-prevalence circulator.<br />
- Three-way electrical valve (Mod. Reply C).<br />
- Proof combustion circuit with high-prevalence flue discharge electrical<br />
fan.<br />
- Water trap siphon<br />
- Class: NOx = 5.<br />
- IP X4D protection degree.<br />
- Containment module structure suitable for external fitting.<br />
Classe<br />
NOx<br />
5<br />
• Installation and Maintenance<br />
- Easy installation thanks to complete supply.<br />
- Maintenance is made simple thanks to easy accessibility to internal<br />
components.<br />
• Optional accessories<br />
- For the accessories suitable for REPLY heating module, see page 85.<br />
- Discharge kits of the heating module are on demand.<br />
• Certification<br />
- REPLY heating modules are EC type approved.<br />
490<br />
230<br />
490<br />
230<br />
315<br />
480<br />
315<br />
480<br />
200<br />
Ø155<br />
255<br />
200<br />
Ø155<br />
255<br />
R eply<br />
R eply<br />
540<br />
1800<br />
540<br />
1800<br />
a1<br />
a4<br />
390<br />
a3<br />
a6<br />
155<br />
390<br />
a3<br />
a2<br />
a6<br />
155<br />
240 300<br />
360 300<br />
a5<br />
140<br />
70<br />
Reply I<br />
1200<br />
140<br />
70<br />
120<br />
1200<br />
Reply C<br />
120<br />
module furnace power useful efficiency Maximum power Heating . Heating gas boiler boiler Cold water Weight<br />
type a 50/30°C a 80/60°C pressure voltage delivery return conn. delivery return inlet<br />
kW kcal/h 100% 30% 100% bar V/Hz DN a1 DN a2 Ø a3 DN a4 DN a5 Ø a6 Kg<br />
REPLY 49 C 8,8÷ 50 7.568÷ 43.000 103,7 106,2 98,1 3 230/50 50 50 1 1/4" 50 50 3/4" 273<br />
module Fuel module 50/30°C useful power 80/60°C useful power<br />
code type kW kcal/h kW kcal/h<br />
00903471 natural gas REPLY 49 C 9,33÷ 51,5 8.022÷ 44.290 8,98÷ 49 7.719÷ 42.140<br />
44