Wall-hung indoor gas boilers<br />
•“wall-hung boiler” ALMA<br />
- High-efficiency open (mod. MB) and proof chamber (mod. MBS)<br />
boilers suitable for hot sanitary water heating and supply.<br />
- 50 Lt. storage unit stainless steel boiler.<br />
- Copper exchanger.<br />
- Atmospheric burner, in stainless steel for all kinds of gas.<br />
- Combustion chamber provided with ceramic fibre insulation.<br />
- Ionization flame control electronic ignition.<br />
- Electronically controlled proportional modulation for heating and<br />
sanitary circuit.<br />
- Suitable for low temperature system operation.<br />
- Proof combustion circuit with flue discharge electrical fan (mod.<br />
MBS).<br />
- Safety FLUE CONTROL preventing burnt gases from entering the<br />
room (mod. MB).<br />
- Slow opening gas valve.<br />
- 8 Lt. heating unit expansion tank.<br />
- 2 Lt. sanitary circuit expansion tank.<br />
- High-prevalence circulator.<br />
- Three-way electrical valve.<br />
- Electronic control panel.<br />
- Heating and sanitary temperature regulation.<br />
- Flue standard intake in the boiler (mod. MBS).<br />
- Defect display.<br />
- Anti-freeze function.<br />
- Post circulation function.<br />
- “antilegionella” function.<br />
- By-pass.<br />
- IP X4D protection degree.<br />
- A digital time and date clock can be fitted.<br />
A<br />
B<br />
C<br />
• Installation and Maintenance<br />
- Easy installation thanks to template connections and water connection<br />
kits (on demand).<br />
- Maintenance is made simple thanks to easy accessibility to internal<br />
components.<br />
• Optional accessories<br />
- For accessories suitable for ALMA boiler, see page 85.<br />
- Flue inlet/outlet kits are not included in the supply. See accessories on<br />
demand on page 85.<br />
• Certification<br />
- ALMA boilers are EC type approved.<br />
900<br />
600 470<br />
232<br />
122<br />
ALMA MBS<br />
dimensions<br />
Attacchi: vedi dima a pag. 79.<br />
boiler furnace power useful efficiency Max. pressure power hot sanitary A B C Weight<br />
type % bar voltage water supply ΔT 30°C<br />
kW kcal/h 100 % 30 % risc. sanit. V/Hz l/min. Ø mm mm mm kg<br />
ALMA 24 MB W TOP/IT 26 22.360 90 86,8 3 8 230/50 11,2 132,5 173 222 70<br />
ALMA 24 MBS W TOP/IT 26 22.360 92 88,7 3 8 230/50 11,4 * 132 222 75<br />
ALMA 28 MB W TOP/IT 30,2 25.972 90,2 86,9 3 8 230/50 13 152,5 173 222 70<br />
ALMA 28 MBS W TOP/IT 30,45 26.187 91,2 88,9 3 8 230/50 13,3 * 132 222 75<br />
ALMA 32 MBS W TOP/IT 34,5 29.670 92,5 88,9 3 8 230/50 15,2 * 132 222 75<br />
* Flue connections: concentric or split discharge - ** Air suction Ø80.<br />
boiler Fuel boiler Useful power<br />
code type kW kcal/h<br />
00905330 natural gas ALMA 24 MB W TOP/IT 10,43÷ 23,4 8.970÷ 20.124<br />
00905340 LPG ALMA 24 MB W TOP/IT 10,43÷ 23,4 8.970÷ 20.124<br />
00905310 natural gas ALMA 24 MBS W TOP/IT 10,5÷ 23,92 9.030÷ 20.571<br />
00905320 LPG ALMA 24 MBS W TOP/IT 10,5÷ 23,92 9.030÷ 20.571<br />
00905370 natural gas ALMA 28 MB W TOP/IT 12,2÷ 27,24 10.492÷ 23.426<br />
00905380 LPG ALMA 28 MB W TOP/IT 12,2÷ 27,24 10.492÷ 23.426<br />
00905350 natural gas ALMA 28 MBS W TOP/IT 12,16÷ 27,8 10.458÷ 23.908<br />
00905360 LPG ALMA 28 MBS W TOP/IT 12,16÷ 27,8 10.458÷ 23.908<br />
00908140 natural gas ALMA 32 MBS W TOP/IT 14÷ 31,9 12.040÷ 27.434<br />
00908150 LPG ALMA 32 MBS W TOP/IT 14÷ 31,9 12.040÷ 27.434<br />