4 - Certificazione energetica edifici
4 - Certificazione energetica edifici
4 - Certificazione energetica edifici
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Pre-mixed condensation gas heating modules<br />
•REPLY N<br />
- Ultra-high efficiency condensation heating module<br />
- Single-furnace (REPLY N 50) or double-furnace (REPLY N 70 and<br />
REPLY N 100) with ultra-high heat exchange aluminium lamellar<br />
exchangers.<br />
- Flame injection pre-mixed ceramic burner.<br />
- Ideal for low temperature system operation.<br />
- Ideal for outdoor installation, even for uncovered places.<br />
- Variable opening pneumatic gas valves.<br />
- Microprocessor electronic card suitable for connection to the cascade<br />
control board and possible external probe.<br />
- Variable speed fans.<br />
- Ionization flame control electronic ignition.<br />
- Electronically controlled continuous modulation with steady air/gas<br />
ratio.<br />
- Natural gas or G.P.L. operation.<br />
- Utility interface display for each module assembled on the machine.<br />
- Instruments for unit control and regulation.<br />
- Independent exchanger water circuits, being connected to the relevant<br />
delivery and return headers.<br />
- Primary unit circulators.<br />
- Check valve.<br />
- Condensation discharge on disposal circuit complete with siphon.<br />
- Silked stainless steel AISI 316 containment module structure, reduced in<br />
size.<br />
- G.P.L. kit supplied with the boiler.<br />
- Class: NOx = 5.<br />
- IP X4D protection degree.<br />
Classe<br />
NOx<br />
5<br />
• Installation and Maintenance<br />
- Series of modules being cascade connected can be managed and easily<br />
assembled. The machine electronic unit is arranged for the connection<br />
of the control room to the cascade control and managament<br />
microprocessor.<br />
- The delivery and return headers for system water delivery and return<br />
and gas adduzione are fitted to the machine; they are flanged in order<br />
to allow easy installation, being complete with blind flanges and<br />
connection system.<br />
- Maintenance is made simple thanks to easy accessibility to internal<br />
components.<br />
1650<br />
Øi 150<br />
a1<br />
400<br />
110<br />
a3<br />
• Optional accessories<br />
- For the accessories suitable for REPLY N heating module, see page 85.<br />
575<br />
390<br />
225<br />
145<br />
a4<br />
a2<br />
• Certification<br />
- REPLY N heating modules are EC type approved.<br />
700<br />
35<br />
115<br />
250<br />
275<br />
module furnace power useful efficiency Maximum power Heating Heating gas condensation Weight<br />
type a 50/30°C a 80/60°C pressure voltage delivery return conn. discharge<br />
kW kcal/h 100% 30% 100% bar V/Hz DN a1 DN a2 DN a3 Ø a4 Kg<br />
REPLY N 50 13,8÷ 46 11.868÷ 39.560 105,3 109 98,2 6 230/50 80 80 50 40 114<br />
REPLY N 70 13,8÷ 70 11.868÷ 60.200 105,3 109 98,2 6 230/50 80 80 50 40 165<br />
REPLY N 100 13,8÷ 92 11.868÷ 79.120 105,3 109 98,2 6 230/50 80 80 50 40 165<br />
module Fuel module 50/30°C useful power 80/60°C useful power<br />
code type kW kcal/h kW kcal/h<br />
00906210 nat. gas/LPG REPLY N 50 14,4÷ 48,4 12.384÷ 41.624 13,6÷ 45,2 11.696÷ 38.872<br />
00906220 nat. gas/LPG REPLY N 70 14,4÷ 73,7 12.384÷ 63.382 13,6÷ 68,7 11.696÷ 59.082<br />
00906230 nat. gas/LPG REPLY N 100 14,4÷ 96,8 12.384÷ 83.248 13,6÷ 90,4 11.696÷ 77.744<br />
46