Pre-mixed condensation gas heating modules<br />

•REPLY N<br />

- Ultra-high efficiency condensation heating module<br />

- Single-furnace (REPLY N 50) or double-furnace (REPLY N 70 and<br />

REPLY N 100) with ultra-high heat exchange aluminium lamellar<br />

exchangers.<br />

- Flame injection pre-mixed ceramic burner.<br />

- Ideal for low temperature system operation.<br />

- Ideal for outdoor installation, even for uncovered places.<br />

- Variable opening pneumatic gas valves.<br />

- Microprocessor electronic card suitable for connection to the cascade<br />

control board and possible external probe.<br />

- Variable speed fans.<br />

- Ionization flame control electronic ignition.<br />

- Electronically controlled continuous modulation with steady air/gas<br />

ratio.<br />

- Natural gas or G.P.L. operation.<br />

- Utility interface display for each module assembled on the machine.<br />

- Instruments for unit control and regulation.<br />

- Independent exchanger water circuits, being connected to the relevant<br />

delivery and return headers.<br />

- Primary unit circulators.<br />

- Check valve.<br />

- Condensation discharge on disposal circuit complete with siphon.<br />

- Silked stainless steel AISI 316 containment module structure, reduced in<br />

size.<br />

- G.P.L. kit supplied with the boiler.<br />

- Class: NOx = 5.<br />

- IP X4D protection degree.<br />

Classe<br />

NOx<br />

5<br />

• Installation and Maintenance<br />

- Series of modules being cascade connected can be managed and easily<br />

assembled. The machine electronic unit is arranged for the connection<br />

of the control room to the cascade control and managament<br />

microprocessor.<br />

- The delivery and return headers for system water delivery and return<br />

and gas adduzione are fitted to the machine; they are flanged in order<br />

to allow easy installation, being complete with blind flanges and<br />

connection system.<br />

- Maintenance is made simple thanks to easy accessibility to internal<br />

components.<br />

1650<br />

Øi 150<br />

a1<br />

400<br />

110<br />

a3<br />

• Optional accessories<br />

- For the accessories suitable for REPLY N heating module, see page 85.<br />

575<br />

390<br />

225<br />

145<br />

a4<br />

a2<br />

• Certification<br />

- REPLY N heating modules are EC type approved.<br />

700<br />

35<br />

115<br />

250<br />

275<br />

module furnace power useful efficiency Maximum power Heating Heating gas condensation Weight<br />

type a 50/30°C a 80/60°C pressure voltage delivery return conn. discharge<br />

kW kcal/h 100% 30% 100% bar V/Hz DN a1 DN a2 DN a3 Ø a4 Kg<br />

REPLY N 50 13,8÷ 46 11.868÷ 39.560 105,3 109 98,2 6 230/50 80 80 50 40 114<br />

REPLY N 70 13,8÷ 70 11.868÷ 60.200 105,3 109 98,2 6 230/50 80 80 50 40 165<br />

REPLY N 100 13,8÷ 92 11.868÷ 79.120 105,3 109 98,2 6 230/50 80 80 50 40 165<br />

module Fuel module 50/30°C useful power 80/60°C useful power<br />

code type kW kcal/h kW kcal/h<br />

00906210 nat. gas/LPG REPLY N 50 14,4÷ 48,4 12.384÷ 41.624 13,6÷ 45,2 11.696÷ 38.872<br />

00906220 nat. gas/LPG REPLY N 70 14,4÷ 73,7 12.384÷ 63.382 13,6÷ 68,7 11.696÷ 59.082<br />

00906230 nat. gas/LPG REPLY N 100 14,4÷ 96,8 12.384÷ 83.248 13,6÷ 90,4 11.696÷ 77.744<br />