Indoor floor-standing gas boilers<br />

•“cast iron, proof” ERA F S<br />

- High-efficiency proof boilers only suitable for heating.<br />

- Cast iron shell with transversal arranged components.<br />

- Stainless steel atmospheric burner for all kinds of gas.<br />

- Intermittent pilot electronic ignition with ionization flame control.<br />

- Instruments for unit control and regulation.<br />

- Proof combustion unit with flue exhaust electrical fan.<br />

- Slow opening gas valve.<br />

- High-prevalence circulator (mod. PK).<br />

- 10 Lt. expansion tank (mod. PK).<br />

- Safety valve (mod. PK).<br />

- Air bleed automatic valve (mod. PK).<br />

- Filling cock (mod. PK).<br />

- Boiler outlet cock.<br />

- ERA F S boilers can be combined with PAC B boilers<br />

• Installation and Maintenance<br />

- Maintenance is made simple thanks to easy accessibility to internal<br />

components (front door).<br />

• Optional accessories<br />

- For accessories suitable for ERA F S boiler, see page 85.<br />

- Flue suction/exhaust kits are not included in the supply<br />

• Certification<br />

- ERA F S boilers are EC type approved.<br />

120<br />

157<br />

850<br />

439 55 55<br />

a1<br />

a3<br />

a2<br />

a4<br />

a5<br />

a7<br />

a6<br />

708 40<br />

182<br />

84<br />

500<br />

600<br />

50<br />

163<br />

boiler furnace power useful efficiency Heating max. power Heating Heating gas Cold water boiler Flue Air Weight<br />

type % pressure voltage delivery return conn. inlet return exhaust suction<br />

kW kcal/h 100 % 30 % bar V/Hz Ø a1 Ø a2 Ø a3 Ø a4 Ø a5 Ø a6 Ø a7 kg<br />

ERA F 32 S 15,9÷ 34,9 13.674÷ 30.014 91,7 90,5 4 230/50 3/4” 3/4” 1/2” - - * 80 170<br />

model equipped with circulator and expansion tank<br />

ERA F 32 S PK 15,9÷ 34,9 13.674÷ 30.014 91,7 90,5 4 230/50 3/4” 3/4” 1/2” 1/2” 1” * 80 180<br />

* Flue connections: concentric or split discharge<br />

boiler boiler Useful power<br />

code type kW kcal/h<br />

00906310 ERA F 32 S* 11÷ 32 9.460÷ 27.520<br />

model equipped with circulator and expansion tank<br />

00903500 ERA F 32 S PK* 11÷ 32 9.460÷ 27.520<br />

57