Wall-hung pre-mixed condensation gas boilers<br />

•FUTURIA L “instantaneous”<br />

- Ultra-high efficiency proof condensation boilers, suitable for hot<br />

sanitary water heating and supply.<br />

- Ideal for low temperature system operation.<br />

- Special casting aluminium corrosion proofing enbloc exchanger.<br />

- Instantaneous exchanger for hot sanitary water with 5 Lt. micro-storage<br />

unit, complete with foamed polyurethane insulation.<br />

- Stainless steel pre-mixing burner.<br />

- Wet-type combustion chamber.<br />

- Ionization flame control electronic ignition.<br />

- Electronically controlled continuous modulation for the heating circuit<br />

with steady air/gas ratio.<br />

- Natural gas or G.P.L. operation.<br />

- Instruments for retraction unit control and regulation.<br />

- High-prevalence circulator.<br />

- 8 Lt. expansion tank.<br />

- Three-way electrical valve.<br />

- Proof combustion circuit with flue discharge electrical fan.<br />

- Water trap siphon<br />

- Class: NOx = 5.<br />

- IP X4D protection degree.<br />

Classe<br />

NOx<br />

5<br />

• Installation and Maintenance<br />

- Easy installation thanks to template connections and water connection<br />

kits (on demand).<br />

- Maintenance is made simple thanks to easy accessibility to internal<br />

components.<br />

• Optional accessories<br />

- For accessories suitable for FUTURIA L boiler, see page 85.<br />

- Flue inlet/outlet kits are not included in the<br />

supply. See accessories on demand on page 85.<br />

- Water connection kits are not included in<br />

the supply. See accessories on demand on<br />

page 85.<br />

120 93<br />

242<br />

• Certification<br />

- FUTURIA L boilers are EC type approved.<br />

900<br />

190 220<br />

450<br />

420<br />

Heat exchanger<br />

boiler furnace power useful efficiency Maximum pressure power hot sanitary Weight<br />

type a 50/30°C a 80/60°C bar voltage water supply. ΔT 30°C<br />

kW kcal/h 100% 30% 100% risc. sanit. V/Hz l/min Kg<br />

FUTURIA L 24 MC W TOP/IT 8,8÷ 25 7.568÷ 21.500 103,7 106,2 98,1 3 6 230/50 2,5÷ 11,7 72<br />

FUTURIA L 28 MC W TOP/IT 10÷ 29 8.600÷ 24.940 102,8 106,6 97,8 3 6 230/50 2,5÷ 13,6 72<br />

* Flue connections: concentric or split discharge<br />

boiler fuel boiler 50/30°C useful power 80/60°C useful power<br />

code type kW kcal/h kW kcal/h<br />

00904501 natural gas FUTURIA L 24 MC W TOP/IT 9,33÷ 25,75 8.022÷ 22.145 8,98÷ 24,5 7.719÷ 21.070<br />

00904511 LPG FUTURIA L 24 MC W TOP/IT 9,33÷ 25,75 8.022÷ 22.145 8,98÷ 24,5 7.719÷ 21.070<br />

00904521 natural gas FUTURIA L 28 MC W TOP/IT 10,66÷ 29,81 9.168÷ 25.634 10,09÷ 28,36 8.677÷ 24.390<br />

00904531 LPG FUTURIA L 28 MC W TOP/IT 10,66÷ 29,81 9.168÷ 25.634 10,09÷ 28,36 8.677÷ 24.390<br />