Wall-hung indoor gas boilers<br />
•“ultra low emission” XILO LN<br />
- Proof boiler suitable for hot sanitary water heating and supply.<br />
- Low NOx emission water cooling burner, in stainless steel for all kinds<br />
of gas.<br />
- Reduced overall dimensions (-20% if compared to the standard<br />
boilers).<br />
- High-efficiency primary copper exchanger.<br />
- Instantaneous exchanger for plate hot sanitary water.<br />
- Ionization flame control electronic ignition.<br />
- Electronically controlled proportional modulation for sanitary and<br />
heating circuits.<br />
- Proof combustion circuit with flue discharge electrical fan.<br />
- By-pass.<br />
- High-prevalence circulator.<br />
- 8 Lt. expansion tank.<br />
- Three-way electrical diverting valve.<br />
- Slow opening gas valve.<br />
- Combustion chamber provided with ceramic fibre insulation.<br />
- Instruments for unit control and regulation.<br />
- Flue standard intake in the boiler (mod. MCS).<br />
- Precedence flow meter.<br />
- Class: NOx = 5.<br />
- IP X4D protection degree.<br />
Classe<br />
NOx<br />
5<br />
• Installation and Maintenance<br />
- Easy installation thanks to template connections and water connection<br />
kits (on demand).<br />
- Maintenance is made simple thanks to easy accessibility to internal<br />
components.<br />
• Optional accessories<br />
- For accessories suitable for XILO LN boiler, see page 85.<br />
- Flue inlet/outlet kits are not included in the supply. See accessories on<br />
demand on page 85.<br />
220<br />
A<br />
160<br />
• Certification<br />
- XILO LN boilers are EC type approved.<br />
770<br />
440 330<br />
97<br />
250<br />
Water cooling burner<br />
boiler furnace power useful efficiency Maximum pressure power voltage hot sanitary A Weight<br />
type % bar water supply ΔT 30°C<br />
kW kcal/h 100 % 30 % risc. sanit. V/Hz l/min. Ø mm kg<br />
XILO LN 20 MCS W TOP/IT 25 21.500 93,9 92,5 3 8 230/50 2,5÷ 11,2 * 43<br />
* Flue connections: concentric or split discharge<br />
boiler fuel boiler useful power<br />
code type kW kcal/h<br />
00903450 natural gas XILO LN 20 MCS W TOP/IT 12,9÷ 23,4 11.094÷ 20.124<br />
00903460 LPG XILO LN 20 MCS W TOP/IT 12,9÷ 23,4 11.094÷ 20.124<br />
48