<strong>04</strong>/<strong>03</strong> <strong>Parameter</strong>s<br />
r0067 CO: Act. output current limit Min: -<br />
Datatype: Float Unit: A Def: -<br />
P-Group: CONTROL Max: -<br />
Level<br />
3<br />
Displays valid maximum output current of inverter.<br />
P<strong>03</strong>05<br />
Motor<br />
Inverter<br />
P0640<br />
r0209<br />
Motor protection<br />
Inverter protection<br />
Min<br />
r0067<br />
Dependency:<br />
This value is influenced by P0640 (Motor overload factor), the derating characteristics and the thermal<br />
motor and inverter protection.<br />
Note:<br />
P0610 (motor I2t temperature reaction) and P0290 (inverter overload reaction) define reaction when limit is<br />
reached.<br />
Normally :<br />
- current limit (r0067) = rated motor current P<strong>03</strong>05 x motor overload factor P0640.<br />
- It is less than or equal to maximum inverter current r0209.<br />
The current limit may be reduced if the motor or inverter thermal model calculation indicates that<br />