<strong>04</strong>/<strong>03</strong> <strong>Parameter</strong>s<br />

1 <strong>Parameter</strong>s<br />

1.1 Introduction to <strong>SINAMICS</strong> <strong>G110</strong> System <strong>Parameter</strong>s<br />

The layout of the parameter description is as follows.<br />

1 Par number 2 <strong>Parameter</strong> name 9 Min:<br />

[index] 3 CStat: 5 Datatype: 7 Unit: 10 Def:<br />

4 P-Group: 6 Active: 8 QuickComm.: 11 Max:<br />

12 Level:<br />

2<br />

13 Description:<br />

1. <strong>Parameter</strong> number<br />

Indicates the relevant parameter number. The numbers used are 4-digit numbers<br />

in the range 0000 to 9999. Numbers prefixed with an “r” indicate that the<br />

parameter is a “read-only” parameter, which displays a particular value but cannot<br />

be changed directly by specifying a different value via this parameter number (in<br />

such cases, dashes “-“ are entered at the points “Unit”, “Min”, “Def” and “Max” in<br />

the header of the parameter description.<br />

All other parameters are prefixed with a “P”. The values of these parameters can<br />

be changed directly in the range indicated by the “Min” and “Max” settings in the<br />

header.<br />

[index] indicates that the parameter is an indexed parameter and specifies the<br />

number of indices available.<br />

2. <strong>Parameter</strong> name<br />

Indicates the name of the relevant parameter.<br />

The BICO system is not available with the <strong>SINAMICS</strong> <strong>G110</strong> inverter. To allow the<br />

parameter names to be used across a variety of inverter types, the names of<br />

parameter have not been changed.<br />

3. Cstat<br />

Commissioning status of the parameter. Three states are possible:<br />

♦ Commissioning C<br />

♦ Run<br />

U<br />

♦ Ready to run T<br />

This indicates when the parameter can be changed. One, two or all three states<br />

may be specified. If all three states are specified, this means that it is possible to<br />

change this parameter setting in all three inverter states.<br />

4. P-Group<br />

Indicates the functional group of the particular.<br />

Note<br />

<strong>Parameter</strong> P00<strong>04</strong> (parameter filter) acts as a filter and focuses access to<br />

parameters according to the functional group selected.<br />

<strong>Parameter</strong> <strong>List</strong> <strong>SINAMICS</strong> <strong>G110</strong><br />

6SL3298-0BA11-0BP0 7