Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
2.4.2 General Specifications<br />
Range<br />
Initial <strong>Drive</strong><br />
0 to 200 Hz<br />
100%/3 Hz (Vector mode)<br />
<strong>Speed</strong> Control Range (Vector mode) 20:1<br />
Frequency control<br />
<strong>Speed</strong> Control<br />
Precision<br />
Setting resolution¡ see note 1<br />
Keypad setting<br />
Display<br />
External signal setting<br />
Frequency limit function<br />
Carrier frequency<br />
V/F pattern<br />
±0.5% (Vector mode)<br />
Digital: 0.1 Hz (0 to 99.9 Hz)/1 Hz (100 to 200 Hz); analogue: 0.06 Hz/ 60 Hz<br />
Set directly with keys or the VR on the keypad<br />
7 segment*3 Displays; frequency/DC Voltage/Output Voltage / Current/ VSD parameters/fault<br />
log/program version/PID feedback control potentiometer.<br />
•External<br />
•Performs up/down controls with multi-functional contacts on the terminal base<br />
Upper/lower frequency limits, and two skip frequencies.<br />
4 to 16 kHz (default 10 kHz, above 10 kHz with De-rating)<br />
6 fixed patterns 50 Hz/60 Hz, 1 programmable<br />
Acc/Dec. control Two-stage acc/dec time (0.1 to 999 s)<br />
Multi-functional analogue<br />
output<br />
Multi-functional input<br />
Multi-functional output<br />
DI (digital input)<br />
DO (digital output)<br />
AI (analogue input)<br />
6 functions (refer to [531] description)<br />
19 functions (refer to [521] to [524] description)<br />
16 functions (refer to [551] description)<br />
NPN/PNP alternative: 4 points standard, 2 points optional (S1 to S4 standard, S5 to S6<br />
optional)<br />
Relay output *Form A contact ---- set to multi-function output. External multi-function output<br />
*option 1 point (open collector transistor 24 V, 600 mA)<br />
Set speed command and PID feedback signal (speed, PID 4–20 mA /0–10 V) or MFIT S7<br />
General control<br />
Other functions<br />
Communication control<br />
Operation temperature<br />
Storage temperature<br />
Instantaneous power loss on restart, <strong>Speed</strong> search, fault restart, DC injection braking,<br />
•RS485 Option card: Modbus RTU/ASCII mode, 4800 to 38400 bps, max. 254 stations<br />
14 to 122F (-10 to 50C) IP20, 14 to 104F (-10 to 40C) IP65<br />
-4 to 140F (-20 to 60C)<br />
Humidity<br />
0 – 95% RH (non condensing)<br />
Vibration immunity 1G (9.8 m/s 2 )<br />
EMI/EMS Compatibility<br />
LVD<br />
Enclosure<br />
Safety Class<br />
Built-in filter in accordance with EN61800-3 first environment<br />
Accordance with EN50178<br />
IP20<br />
UL508C<br />
<strong>Emotron</strong> AB 01-3993-01r3 Mounting and installation of the <strong>VSA</strong> drive 15