Preface<br />

Preface<br />

To extend the performance of the product and ensure personnel<br />

safety, read this manual thoroughly before using the<br />

variable speed drive (VSD). Should there be any problem in<br />

using the product that can not be solved with the information<br />

provided in the manual, contact your nearest <strong>Emotron</strong><br />

distributor or sales representative who will be willing to help<br />

you.<br />

Precautions<br />

The VSD is an electrical product. For your safety, there are<br />

symbols such as “Danger”, “Caution” in this manual as a<br />

reminder to pay attention to safety instructions on carrying,<br />

installing, operating, and checking the VSD. Be sure to follow<br />

the instructions for maximum safety.<br />

WARNING: Indicates a potential hazard could<br />

cause death or serious personal injury if<br />

misused.<br />

Product Inspection<br />

The variable speed drives have all passed the function test<br />

before delivery. Please check the following when you receive<br />

and unpack the VSD:<br />

• The model and capacity of the VSD is the same as those<br />

specified on your order.<br />

• Is there any damage caused by transportation, do not<br />

apply the power.<br />

Contact <strong>Emotron</strong>’s sales representatives if any of the<br />

above problems have occurred.<br />

Earthing<br />

The variable speed drive must always be earthed via the<br />

mains safety earth connection, indicated by “PE”.<br />

Earth leakage current<br />

This VSD has an earth leakage current which does exceeding<br />

3.5 mA a.c. or 10 mA d.c. Therefore the minimum size of<br />

the protective earth conductor must comply with the local<br />

safety regulations for high leakage current equipment.<br />

!<br />

CAUTION: Indicates that the VSD or the<br />

mechanical system might be damaged if<br />

misused.<br />

WARNING: Do not touch any circuit boards or<br />

components if the charging indicator is still<br />

lit after the power off is turned off.<br />

Residual current device (RCD)<br />

compatibility<br />

This product cause a d.c. current in the protective conductor.<br />

Where a residual current device (RCD) is used for protection<br />

in case of direct or indirect contact, only a Type B<br />

RCD is allowed on the supply side of this product. Use<br />

RCD of 300 mA minimum.<br />

Do not wire when the VSD is electrified. Do not check<br />

parts and signals on circuit boards during the VSD<br />

operation.<br />

Do not disassemble the VSD or modify internal wires,<br />

circuits and parts.<br />

Earth the ground terminal of the VSD properly. As per<br />

200 V class, earth to 100 Ohm and 400 V class, earth to<br />

10 Ohm or below.<br />

!<br />

CAUTION: Do not perform a voltage test on<br />

parts inside the VSD. High voltage will easily<br />

destroy these semiconductor parts.<br />

Do not connect the VSD’s T1 (U), T2 (V) and T3 (W)<br />

terminals to an AC power supply.<br />

CMOS ICs on the VSD’s main board are susceptible to<br />

static electricity. Do not touch the main circuit board<br />