Preface<br />
Preface<br />
To extend the performance of the product and ensure personnel<br />
safety, read this manual thoroughly before using the<br />
variable speed drive (VSD). Should there be any problem in<br />
using the product that can not be solved with the information<br />
provided in the manual, contact your nearest <strong>Emotron</strong><br />
distributor or sales representative who will be willing to help<br />
you.<br />
Precautions<br />
The VSD is an electrical product. For your safety, there are<br />
symbols such as “Danger”, “Caution” in this manual as a<br />
reminder to pay attention to safety instructions on carrying,<br />
installing, operating, and checking the VSD. Be sure to follow<br />
the instructions for maximum safety.<br />
WARNING: Indicates a potential hazard could<br />
cause death or serious personal injury if<br />
misused.<br />
Product Inspection<br />
The variable speed drives have all passed the function test<br />
before delivery. Please check the following when you receive<br />
and unpack the VSD:<br />
• The model and capacity of the VSD is the same as those<br />
specified on your order.<br />
• Is there any damage caused by transportation, do not<br />
apply the power.<br />
Contact <strong>Emotron</strong>’s sales representatives if any of the<br />
above problems have occurred.<br />
Earthing<br />
The variable speed drive must always be earthed via the<br />
mains safety earth connection, indicated by “PE”.<br />
Earth leakage current<br />
This VSD has an earth leakage current which does exceeding<br />
3.5 mA a.c. or 10 mA d.c. Therefore the minimum size of<br />
the protective earth conductor must comply with the local<br />
safety regulations for high leakage current equipment.<br />
!<br />
CAUTION: Indicates that the VSD or the<br />
mechanical system might be damaged if<br />
misused.<br />
WARNING: Do not touch any circuit boards or<br />
components if the charging indicator is still<br />
lit after the power off is turned off.<br />
Residual current device (RCD)<br />
compatibility<br />
This product cause a d.c. current in the protective conductor.<br />
Where a residual current device (RCD) is used for protection<br />
in case of direct or indirect contact, only a Type B<br />
RCD is allowed on the supply side of this product. Use<br />
RCD of 300 mA minimum.<br />
Do not wire when the VSD is electrified. Do not check<br />
parts and signals on circuit boards during the VSD<br />
operation.<br />
Do not disassemble the VSD or modify internal wires,<br />
circuits and parts.<br />
Earth the ground terminal of the VSD properly. As per<br />
200 V class, earth to 100 Ohm and 400 V class, earth to<br />
10 Ohm or below.<br />
!<br />
CAUTION: Do not perform a voltage test on<br />
parts inside the VSD. High voltage will easily<br />
destroy these semiconductor parts.<br />
Do not connect the VSD’s T1 (U), T2 (V) and T3 (W)<br />
terminals to an AC power supply.<br />
CMOS ICs on the VSD’s main board are susceptible to<br />
static electricity. Do not touch the main circuit board<br />
<strong>Emotron</strong> AB 01-3993-01r3