Rendamax<br />

2.2.1 Description of principal components<br />

<strong>The</strong> boiler is constructed from the following principal compo nents:<br />

Fan [26]<br />

<strong>The</strong> DC fan, which is equipped with a speed feedback, draws in the combustion air and increases<br />

the air pressure. <strong>The</strong> speed feedback signal is relayed to the regulator, which adjusts the speed if<br />

need be.<br />

Gas train<br />

<strong>The</strong> principal component of the gas train is the main gas valve [25]. <strong>The</strong> quantity of gas is adjusted<br />

in proportion to the quantity of air being supplied. <strong>The</strong> quantity of air depends on the speed of<br />

the fan. As an option, the unit can be equipped with a gas filter [27].<br />

Burner [4]<br />

After the gas/air mixture has been distributed over the burner using a distribution plate, the mixture<br />

is burnt on the burner surface such that the flame is directed downward. <strong>The</strong> burner is both<br />

air and water-cooled. <strong>The</strong> water headers are constructed of cast iron (stainless steel for water<br />

heater), and ensure a two-pass flow through the burner.<br />

Heat exchangers [6, 7 and 8]<br />

<strong>The</strong> first heat exchanger is constructed of smooth stainless steel pipes and transfers most of the<br />

combustion energy to the system water. <strong>The</strong> second heat exchanger is constructed of laser-welded,<br />

stainless steel finned pipes. <strong>The</strong> third heat exchanger is constructed of smooth stainless<br />

steel pipes. <strong>The</strong> second and third heat exchanger transfer the heat from the combustion gasses to<br />

the system water. All water headers are constructed of cast iron (stainless steel for water heaters),<br />

and ensure a five-pass or three-pass flow through the heat exchangers (depending on the<br />

type). <strong>The</strong> space between the burner and the first heat exchanger constitutes the combustion<br />

chamber.<br />

Water headers [21]<br />

<strong>The</strong> water headers are part of the burner and the heat exchangers.<br />

Water connections<br />

<strong>The</strong>se consist of a flow connection [13] and a return connection [19]. Both of these connections are<br />

provided with a filling/drain valve [18]. <strong>The</strong> flow switch [20] is fitted on the flow line.<br />

Boiler pump (optional)<br />

<strong>The</strong> boiler pump must be mounted on the return connection to the unit and can be directly connected<br />

electrically to the appropriate terminals in the connection box. <strong>The</strong> capacity and the working<br />

head of the pump is sufficient to overcome both the resistance of the boiler and some system<br />

resistance. As an option, the pump is supplied as a separate item with the boiler.<br />

Condensate receptacle [9]<br />

A condensate receptacle is fitted underneath the last heat exchanger. This receptacle is equipped<br />

with a condensate and flue gas outlet.<br />

Frame [17]<br />

<strong>The</strong> frame is constructed from steel profile sections and is fitted with vibration absorbing adjusting<br />

feet [16].<br />

Casing [1]<br />

<strong>The</strong> casing consists of easy-to-remove panels. Once the cover has been opened (using tools), all<br />

other panels can be removed without using tools.<br />

<strong>The</strong> electrical section<br />

This includes the control and safety circuits for the unit.<br />