Cooper B-Line Pipe Hangers & Supports - Dixie Construction Products
Cooper B-Line Pipe Hangers & Supports - Dixie Construction Products
Cooper B-Line Pipe Hangers & Supports - Dixie Construction Products
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Miscellaneous Assemblies<br />
ASSEMBLY 1 ASSEMBLY 2 ASSEMBLY 3<br />
B-<strong>Line</strong><br />
Fig. B3031- 3 /8<br />
B-<strong>Line</strong><br />
Fig. B3034<br />
B-<strong>Line</strong><br />
Fig. B3036L<br />
Miscellaneous<br />
Assemblies<br />
B-<strong>Line</strong><br />
Fig. B3170<br />
B-<strong>Line</strong><br />
Fig. B3170<br />
B-<strong>Line</strong><br />
Fig. B3170<br />
NOTES:<br />
1. Size hanger and clamp to adequarely<br />
support load (refer to <strong>Cooper</strong> B-<strong>Line</strong> pipe<br />
hanger catalog).<br />
2. For NFPA rod sizes use B3170NF.<br />
3. For copper tubing use copper plated or<br />
painted B3170CT, felt lined B3170F or<br />
plastic coated hangers.<br />
4. For more secure attachment use B3367<br />
retaining strap with B3031.<br />
NOTES:<br />
1. Size hanger and clamp to adequarely<br />
support load (refer to <strong>Cooper</strong> B-<strong>Line</strong> pipe<br />
hanger catalog).<br />
2. For NFPA rod sizes use B3170NF.<br />
3. For copper tubing use copper plated or<br />
painted B3170CT, felt lined B3170F or<br />
plastic coated hangers.<br />
4. For flange thicknesses greater than 3 /4"<br />
use wide jaw top C-Clamp B3033.<br />
5. For more secure attachment use B3367<br />
retaining strap with B3034.<br />
NOTES:<br />
1. Size hanger and clamp to adequarely<br />
support load (refer to <strong>Cooper</strong> B-<strong>Line</strong> pipe<br />
hanger catalog).<br />
2. For NFPA rod sizes use B3170NF.<br />
3. For copper tubing use copper plated or<br />
painted B3170CT, felt lined B3170F or<br />
plastic coated hangers.<br />
4. B3036L also available without locknut as<br />
B3036.<br />
5. For more secure attachment use B3363<br />
retaining strap with B3036L.<br />
ASSEMBLY 4 ASSEMBLY 5 ASSEMBLY 6<br />
B-<strong>Line</strong><br />
Fig. B351L<br />
B-<strong>Line</strong><br />
Fig. B3060<br />
B-LINE<br />
FIG. B2501<br />
B-<strong>Line</strong><br />
Fig. B3170<br />
B-<strong>Line</strong><br />
Fig. B3170<br />
B-<strong>Line</strong><br />
Fig. B3170<br />
NOTES:<br />
1. Size hanger and clamp to adequarely<br />
support load (refer to <strong>Cooper</strong> B-<strong>Line</strong> pipe<br />
hanger catalog).<br />
2. B351L is UL Approved.<br />
3. For NFPA rod sizes use B3170NF.<br />
4. For copper tubing use copper plated or<br />
painted B3170CT, felt lined B3170F or<br />
plastic coated hangers.<br />
5. For more secure attachment use B3362<br />
retaining strap with B351.<br />
NOTES:<br />
1. Size hanger and angle clip to adequarely<br />
support load (refer to <strong>Cooper</strong> B-<strong>Line</strong> pipe<br />
hanger catalog).<br />
2. For NFPA rod sizes use B3170NF.<br />
3. For copper tubing use copper plated or<br />
painted B3170CT, felt lined B3170F or<br />
plastic coated hangers.<br />
NOTES:<br />
1. Size hanger and concrete insert to<br />
adequarely support load (refer to <strong>Cooper</strong><br />
B-<strong>Line</strong> pipe hanger catalog).<br />
2. For NFPA rod sizes use B3170NF.<br />
3. For copper tubing use copper plated or<br />
painted B3170CT, felt lined B3170F or<br />
plastic coated hangers.<br />
4. Size insert to thread size.<br />
216