SYNCHRONIZING DUAL HELMS PRIOR TO STATION TRANSFER<br />
Section 2 - Getting to Know Your Power Package<br />
Pressing the station select button and holding it in allows the boat operator 10 seconds to<br />
match up the control handle settings at the new station with the handle settings that are at<br />
the old (to be inactive) station. If the handles are not matched, the neutral light will flash.<br />
The light blinks faster as the handles are nearing match position. Once the light stays on<br />
continuously, the handles are matched and the button can be released. Transfer process<br />
is complete and the new station is now in control. If the button is held for over 10 seconds,<br />
the station transfer is cancelled.<br />
Zero Effort Features<br />
a<br />
b<br />
a - Shift ever<br />
17357<br />
b - Throttle lever<br />
Shift Lever - Shift functions are controlled by the movement of the shift lever. Shift into<br />
reverse by moving the shift lever to its aft position. Shift into neutral by moving the shift<br />
lever to its center position. Shift into forward by moving the shift lever to its forward position.<br />
Throttle Lever - Throttle functions are controlled by the movement of the throttle lever.<br />
Increase the RPM by moving the throttle lever forward. Achieve Wide Open Throttle (WOT)<br />
by placing the throttle lever in its full forward position. Decrease RPM by moving the throttle<br />
lever back. Achieve minimum RPM (idle) by placing the throttle lever in its full aft position.<br />
Electrical System Overload Protection<br />
If an electrical overload occurs, a fuse will blow or the circuit breaker will trip open. The<br />
cause must be found and corrected before replacing the fuse or resetting the circuit<br />
breaker.<br />
IMPORTANT: Always store spare fuses in the boat for replacement.<br />
NOTE: In an emergency, when the engine must be operated and the cause for the high<br />
current draw cannot be located and corrected, turn off or disconnect all accessories<br />
connected to the engine and instrumentation wiring. Reset the circuit breaker. If the breaker<br />
remains open, the electrical overload has not been eliminated. Further checks must be<br />
made on the electrical system. Contact your authorized dealer.<br />