TECHNICAL<br />

PERFORMANCE<br />

External Fabric<br />

300mm cavity wall consisting of an external<br />

brickwork skin, 100m cavity fully filled with<br />

100mm mineral wool insulation and an internal<br />

skin of 100mm ultra lightweight aggregate<br />

blocks, finished using standard plasterboard<br />

on dabs. U-value of 0.28W/m 2 K<br />

Roof<br />

Pitched timber truss, concrete interlocking<br />

tiles, 400mm mineral wool insulation laid<br />

in two layers with the first of 200mm laid<br />

between ceiling joists with second layer<br />

of 200mm laid at 90 degrees to first over<br />

ceiling joists. U-value of 0.17W/m 2 K<br />

Floor<br />

100mm concrete slab over a layer of<br />

120mm urethane insulation. U-value<br />

of 0.15W/m 2 K<br />

Doors and Windows<br />

SCHEME<br />

IMPLEMENTATION<br />

The design of the completed units is typical<br />

of newer <strong>homes</strong> in the surrounding area,<br />

with only the photovoltaic cells installed on<br />

some of the rented units presenting any<br />

less-than-usual external features on the<br />

development. The low energy merits of the<br />

housing were considered a very desirable<br />

attribute <strong>for</strong> this development, and the<br />

photovoltaic cells were installed to address<br />

fuel poverty issues.<br />

The developer was keen to demonstrate<br />

that achieving <strong>Code</strong> Level 3 did not require<br />

significant changes to its standard housing<br />

types. Minimal changes to the super structure<br />

of the building were required and primarily<br />

achieved through higher levels of insulation<br />

in the roof and the inclusion of a heat recovery<br />

exhaust air heating and hot water system.<br />

Training was provided by the supplier of the<br />

heat recovery exhaust air heating and hot<br />

water system <strong>for</strong> local plumbers in order<br />

to effectively install the system.<br />

The development during construction<br />

Double glazed uPVC windows and doors.<br />

U-value of 1.8W/m 2 K<br />

Air-permeability<br />

The target was 7m 3 /h@50pa which was<br />

achieved by all units during the final air<br />

permeability tests, with a small number<br />

of units achieving improvements on this.<br />

CASE STUDY 5 | CODE FOR SUSTAINABLE HOMES | 13