Model Z 10-60 20-30 36-18 60-10 100-6<br />
Programming and readback (RS232/485, USB, Optional: IEEE; LAN)<br />
Vout programming accuracy<br />
Iout programming accuracy (*13)<br />
Vout programming resolution<br />
Iout programming resolution<br />
Vout readback accuracy<br />
Iout readback accuracy (*13)<br />
Vout readback resolution<br />
Iout readback resolution<br />
0.05 % of rated output voltage<br />
0.1 % of actual +0.1 % rated output current<br />
0.012 % of full scale<br />
0.012 % of full scale<br />
0.05 % of rated output voltage<br />
0.1 % of actual +0.3 % rated output current<br />
0.012 % of full scale<br />
0.012 % of full scale<br />
Input Characteristics<br />
Input voltage/freq. (*3)<br />
85~265 V AC continuous, 47~63 Hz, Single-Phase<br />
Maximum Input current 100/200 V AC (*18) 7.4/3.6 7.24/3.53 7.73/3.77 7.15/3.5 7.15/3.5<br />
Power Factor (Typ)<br />
0.99 at 100/200 V AC, 100 % load<br />
Efficiency (Typ) 100/200VAC (*4) (*18) [%] 82/84 84/86 85/87 85/87 85/87<br />
Inrush current (*5)<br />
Less than 25 A<br />
Environmental Conditions<br />
Operating temperature<br />
0~50 °C, 100 % load.<br />
Storage temperature -20~85 °C<br />
Operating humidity [%] 20~90 % RH (no condensation).<br />
Storage humidity [%] 10~95 % RH (no condensation).<br />
Altitude Maximum 3000 m. Derate ambient temp above 2000 m.<br />
Operating: Maximum ambient temperature, from 2000 m up to 3000 m<br />
Ambient temperature 40 °C.<br />
Safety/EMC<br />
Applicable standards: Safety UL61010-1, EN61010-1, IEC61010-1. Design to meet UL60950-1, EN60950-1<br />
EMC<br />
IEC61326-1 (Built to meet EN55022/EN55024)<br />
Withstand voltage Safety 10 ≤ Vout ≤ 36V models: Input-Output & J1, J2, J3, J4, USB, LAN/IEEE/<br />
ISOLATED ANALOG: 4242 V DC / 1 min; Input-Ground: 2828 V DC / 1 min.<br />
Output & J1, J2, J3, J4, USB, LAN/IEEE/ISOLATED ANALOG-Ground:<br />
1000 V DC / 1 min.<br />
60 V, 100 V models: Input-Output & J1, J2: 4242 V DC / 1 min; Input-J3, J4,<br />
USB, LAN/IEEE/ISOLATED Analog: 4242 V DC / 1 min; Input-Ground: 2828<br />
V DC / 1 min.<br />
Output & J1, J2 - J3, J4, USB, LAN/IEEE/ISOLATED ANALOG:<br />
1910 V DC / 1 min; Output & J1, J2-Ground: 1380 V DC / 1 min.<br />
J3, J4, USB/LAN/IEEE/ISOLATED ANALOG - Ground: 1000 V DC / 1 min;<br />
Insulation resistance<br />
More than 100 MΩ at 25 °C, 70 % RH.<br />
Conducted emission<br />
EN55022B, FCC part 15-B, VCCI-B<br />
Radiated emission<br />
EN55022B, FCC part 15-B, VCCI-B<br />
Mechanical<br />
Cooling<br />
Forced air cooling by internal fan.<br />
Weight Standard [kg] Less than 2.5 kg<br />
Wide Body<br />
Less than 3.0 kg. Wide body with Isolated analog or Binding post or IEEE.<br />
Dimensions<br />
(W x H x D)<br />
Standard [mm] H: 83, W: 70, D: 350 (excluding bus bars, handles…).<br />
(Refer to Outline drawing).<br />
Wide Body<br />
H: 83, W: 105, D: 350 (excluding bus bars, handles…).<br />
(Refer to Outline drawing).<br />
Shock<br />
According to: IEC60068-2-64<br />
Less than 20 G, half sine, 11 ms. Unit is unpacked. According to:<br />
IEC600068-2-27<br />
*12: For 10 V model the ripple is measured at 2 V to rated output voltage and rated<br />
output current. For other models, the ripple is measured at 10~100 % of rated<br />
output voltage and rated output current.<br />
*13: The Constant Current programming, readback and monitoring accuracy do not<br />
include the warm-up and Load regulation thermal drift.<br />
*14: Measured with JEITA RC-9131A (1:1) probe.<br />
*15: For cases where the time interval between each down programming is longer<br />
than Td (time delay).<br />
*16: For cases where the time interval between each down programming is shorter than<br />
Td (time delay).<br />
*17: Td typical (±20 %) Minimum time between consecutive down programming cycles.<br />
*18: PS with isolated analog option decreases efficiency by 0.5 % and increases input<br />
current by 0.5 %<br />