Interface RS-232 & RS-485 or Optional GPIB / LAN Interface GEN 8-400 10-330 15-220<br />

Model [V] 8 10 15<br />

Remote Current Programming (16 bit)<br />

Resolution (0.012 % of lo Rated) [mA] 48 39.6 26.4<br />

Accuracy (0.2 % of lo Rated + 0.1 % of lo Actual Output) (*10) [mA] 1200 990 660<br />

Readback Current<br />

Resolution (0.012 % of lo Rated) [mA] 48 39.6 26.4<br />

Accuracy (0.3 % of lo Rated + 0.1 % of lo Actual Output) (*10) [mA] 1600 1320 880<br />

Remote Voltage Programming (16 bit)<br />

Resolution (0.012 % of Vo Rated) [mV] 0.96 1.2 1.8<br />

Accuracy (0.05 % Vo Rated + 0.05 % of Vo Actual Output) [mV] 8 10 15<br />

Readback Voltage<br />

Resolution (0.012 % of Vo Rated) [mV] 0.96 1.2 1.8<br />

Accuracy (0.1 % Vo Rated + 0.1 % of Vo Actual Output) [mV] 16 20 30<br />

OVP/UVL Programming<br />

Resolution (0.1 % of Vo Rated) [mV] 8 10 15<br />

Accuracy (1 % of Vo Rated) [mV] 80 100 150<br />

Analog Programming and Monitoring<br />

Vout Voltage Programming<br />

Iout Voltage Programming (*10)<br />

Vout Resistor Programming<br />

Iout Resistor Programming (*10)<br />

On/Off control (rear panel)<br />

Output current monitor (*10)<br />

Output voltage monitor<br />

Power supply OK signal<br />

CV/CC indicator<br />

0~100 %, 0~5 V or 0~10 V, user-selectable.<br />

Accuracy and linearity: ± 0.5 % of rated Vout.<br />

0~100 %, 0~5 V or 0~10 V, user-selectable.<br />

Accuracy and linearity: ± 1 % of rated lout.<br />

0~100 %, 0~5/10 kΩ full scale, user-selectable.<br />

Accuracy and linearity: ± 1 % of rated Vout.<br />

0~100 %, 0~5/10 kΩ full scale, user-selectable.<br />

Accuracy and linearity: ± 1.5 % of rated lout.<br />

By electrical. Voltage: 0~0.6 V/2~15 V, or dry contact, user-selectable logic<br />

0~5 V or 0~10 V, accuracy: ± 1 %, user-selectable<br />

0~5 V or 0~10 V, accuracy: ± 1 %, user-selectable<br />

TTL high (2~15 V) -OK, 0 V-Fail 500 Ω series resistance<br />

Open collector. CC mode: On, CV mode: Off. Maximum voltage: 30 V, maximum sink<br />

current: 10 mA.<br />

Enable/Disable<br />

Dry contact. Open: off, Short: on. Max. voltage at Enable/Disable in: 6 V<br />

Local/Remote analog control<br />

By electrical signal or Open/Short: 0~0.6 V or short: Remote, 2~15 V or open: Local<br />

Local/Remote analog control indicator Open collector, Local: Open, Remote: On. Maximum voltage: 30 V,<br />

maximum sink current: 10 mA<br />

*10: The Constant Current programming readback and monitoring accuracy does not include the warm-up and Load regulation thermal drift.<br />